MedPath

Maximising Time With a Normal Blood Glucose to Restore the Glucagon Response in Type 1 Diabetes

Not Applicable
Active, not recruiting
Conditions
Hypoglycemia
Insulin Hypoglycemia
Type 1 Diabetes
Hypoglycemia Unawareness
Glucagon Deficiency
Type 1 Diabetes Mellitus With Hypoglycemia
Interventions
Procedure: Stepped hyperinsulinaemic-hypoglycaemic clamp study
Device: Blinded continuous glucose monitor
Device: Insulin pump
Procedure: Stable isotope studies- D2 Glucose and D5 Glycerol
Device: Continuous glucose monitor
Other: Low carbohydrate diet
Registration Number
NCT04614168
Lead Sponsor
University of Edinburgh
Brief Summary

Almost all people who have had type 1 diabetes for 5 years have a defect in secretion of the hormone Glucagon. This hormone is involved in the body's response to low blood glucose (hypoglycaemia). It works by releasing glucose stores from the liver to bring the blood glucose back to normal. This defect therefore increases the risk of severe hypoglycaemia. The reason for this Glucagon defect in people with Type 1 diabetes is currently unknown.

This study aims to look at the Glucagon response to hypoglycaemia in 24 people with type 1 diabetes to ascertain whether tight blood glucose control over a period of time improves this response. The investigators aim to achieve good blood glucose control using new generation Automated Insulin Delivery systems (AIDs). This system is made of: an insulin pump, a continuous glucose monitor (CGM) and an algorithm that allows adjustment of insulin delivery based on the blood glucose readings from the CGM. This is the most up to date technology that there is in the management of type 1 diabetes. However, people using this technology often still have problems with high blood glucose after eating. To ensure a very good blood glucose control participants will also follow a low carbohydrate diet to prevent this blood glucose rise after meals.

The Glucagon response to low blood glucose will be measured at zero and eight months using the hyperinsulinaemic hypoglycaemic clamp technique.

Detailed Description

This is a feasibility pilot study involving 24 participants with type 1 diabetes. Participants will be recruited from the local type 1 diabetes clinic and insulin pump waiting list. Each participant will enter the trial for a period of 8 months. The investigators aim to test if maximising time in glycaemic range (blood glucose 3.9-10 mmol/L) will restore the glucagon response to insulin-induced hypoglycaemia.

After signing informed consent participants will be screened for eligibility against the inclusion and exclusion criteria.

Those who are eligible will have an initial 20-day period of baseline blood glucose data collection. This will be achieved using a blinded continuous glucose monitoring (CGM) device. Participants will continue on their pre-trial diabetes care during this period and will be required to monitor their own blood glucose as normal.

The participants will be split into two groups using stratified sampling to match for: age, gender and BMI.

Group 1 will be the control group. Participants in this group will continue on standard diabetes care for the duration of the trial. Participants will be required to undertake two further periods of blinded CGM monitoring at 4 and 8 months.

Group 2 will be the intervention group. Participants in this group will be placed on the automated insulin delivery (AID) system and asked to follow a low carbohydrate diet of 30-40g of carbohydrate per main meal portion. The AID system will consist of: a Tandem t:slim X2 insulin pump with control IQ technology and a Dexcom G6 continuous glucose monitor. After receiving training on the use of the devices these participants will enter a 2 week study run-in period to become accustomed to the devices and so that device settings can be optimised. As a safety measure these participants will be asked to measure blood ketones at least once daily throughout the trial. Study staff will monitor the data from the participants study devices throughout the trial and adjust settings as required to maximise time in glycaemic range.

At the beginning and end of the trial all participants will undergo a hyperinsulinaemic hypoglycaemic clamp study to measure their counterregulatory hormone response to hypoglycaemic. Participants will also undergo cognitive tests and assessment of hypoglycaemic awareness during each clamp study.

Recruitment & Eligibility

Status
ACTIVE_NOT_RECRUITING
Sex
All
Target Recruitment
17
Inclusion Criteria
  • Participants with Type 1 diabetes with C-peptide levels less than 200pmol/L.
  • Type 1 diabetes for 5 years or more.
  • HbA1c greater than or equal to 53 mol/mol.
  • Normal renal function.
  • Normal thyroid function.
  • Gold Score 4-7 (indicating impaired awareness of hypoglycaemia)
  • Willingness to monitor blood ketones daily.
  • Use of freestyle libre device is permitted at study entry and may be continued in participants in group 1
Exclusion Criteria
  • Current use of a non-approved closed loop / AID system or those on a predictive low glucose suspend insulin pump.
  • Proliferative retinopathy
  • Regular use of real time CGM in the preceding 3 months.
  • History of Diabetic ketoacidosis in the preceding 6 months.
  • Severe hypoglycaemic episode requiring external assistance in the preceding 6 months.
  • Inability to safely use technology used in this study (e.g. impaired vision, memory or dexterity that prevents safe operation of CGM or insulin pump.)
  • Inability to support the technology requirements for the study (e.g. unable to upload study device at home)
  • History of Haemophilia, Cystic Fibrosis, pancreatic disease or complete pancreatectomy, ischaemic heart disease, epilepsy or hypoglycaemia induced seizure
  • History of severe reaction or allergy to adhesive necessary to this study.
  • Unable to adhere to study timetable.
  • Unable to give informed consent.
  • Pregnancy. We will perform a pregnancy test on all eligible participants at baseline.
  • Concurrent use of any non-insulin glucose-lowering agent (including GLP-1 agonists, Symlin, DPP-4 inhibitors, SGLT-2 inhibitors, sulfonylureas. These may lower insulin requirements and predispose to diabetic ketoacidosis.
  • Concurrent use of medication that may affect blood glucose such as SSRIs
  • A condition, which in the opinion of the investigator, would put the patient or study at risk
  • HbA1c greater than or equal to 75 mmol/mol

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Group 1 - Standard CareStepped hyperinsulinaemic-hypoglycaemic clamp studyThis group will continue on their standard diabetes care. They will be required to undergo three periods of blinded continuous glucose monitoring each lasting 20-days at: baseline, 4 months and 8 months. Participants in this group will undergo a hyperinsulinaemic hypoglycaemic clamp study at baseline and 8 months. They will also complete quality of life and diabetes treatment questionnaires at baseline and 8 months.
Group 1 - Standard CareBlinded continuous glucose monitorThis group will continue on their standard diabetes care. They will be required to undergo three periods of blinded continuous glucose monitoring each lasting 20-days at: baseline, 4 months and 8 months. Participants in this group will undergo a hyperinsulinaemic hypoglycaemic clamp study at baseline and 8 months. They will also complete quality of life and diabetes treatment questionnaires at baseline and 8 months.
Group 1 - Standard CareStable isotope studies- D2 Glucose and D5 GlycerolThis group will continue on their standard diabetes care. They will be required to undergo three periods of blinded continuous glucose monitoring each lasting 20-days at: baseline, 4 months and 8 months. Participants in this group will undergo a hyperinsulinaemic hypoglycaemic clamp study at baseline and 8 months. They will also complete quality of life and diabetes treatment questionnaires at baseline and 8 months.
Group 2- Automated insulin delivery and low carbohydrate dietLow carbohydrate dietThis group will be placed on an automated insulin delivery system: Tandem t:slim x2 insulin pump with Control IQ technology and Dexcom G6 continuous glucose monitor. They will also be asked to follow a low-carbohydrate diet of 30-40g of carbohydrate per main meal. At baseline they will have a 20-day period of blinded continuous glucose monitoring. Participants in this group will undergo a stepped hyperinsulinaemic hypoglycaemic clamp study at baseline and 8 months. They will also complete quality of life and diabetes treatment questionnaires at baseline and 8 months.
Group 2- Automated insulin delivery and low carbohydrate dietStepped hyperinsulinaemic-hypoglycaemic clamp studyThis group will be placed on an automated insulin delivery system: Tandem t:slim x2 insulin pump with Control IQ technology and Dexcom G6 continuous glucose monitor. They will also be asked to follow a low-carbohydrate diet of 30-40g of carbohydrate per main meal. At baseline they will have a 20-day period of blinded continuous glucose monitoring. Participants in this group will undergo a stepped hyperinsulinaemic hypoglycaemic clamp study at baseline and 8 months. They will also complete quality of life and diabetes treatment questionnaires at baseline and 8 months.
Group 2- Automated insulin delivery and low carbohydrate dietInsulin pumpThis group will be placed on an automated insulin delivery system: Tandem t:slim x2 insulin pump with Control IQ technology and Dexcom G6 continuous glucose monitor. They will also be asked to follow a low-carbohydrate diet of 30-40g of carbohydrate per main meal. At baseline they will have a 20-day period of blinded continuous glucose monitoring. Participants in this group will undergo a stepped hyperinsulinaemic hypoglycaemic clamp study at baseline and 8 months. They will also complete quality of life and diabetes treatment questionnaires at baseline and 8 months.
Group 2- Automated insulin delivery and low carbohydrate dietContinuous glucose monitorThis group will be placed on an automated insulin delivery system: Tandem t:slim x2 insulin pump with Control IQ technology and Dexcom G6 continuous glucose monitor. They will also be asked to follow a low-carbohydrate diet of 30-40g of carbohydrate per main meal. At baseline they will have a 20-day period of blinded continuous glucose monitoring. Participants in this group will undergo a stepped hyperinsulinaemic hypoglycaemic clamp study at baseline and 8 months. They will also complete quality of life and diabetes treatment questionnaires at baseline and 8 months.
Group 2- Automated insulin delivery and low carbohydrate dietBlinded continuous glucose monitorThis group will be placed on an automated insulin delivery system: Tandem t:slim x2 insulin pump with Control IQ technology and Dexcom G6 continuous glucose monitor. They will also be asked to follow a low-carbohydrate diet of 30-40g of carbohydrate per main meal. At baseline they will have a 20-day period of blinded continuous glucose monitoring. Participants in this group will undergo a stepped hyperinsulinaemic hypoglycaemic clamp study at baseline and 8 months. They will also complete quality of life and diabetes treatment questionnaires at baseline and 8 months.
Group 2- Automated insulin delivery and low carbohydrate dietStable isotope studies- D2 Glucose and D5 GlycerolThis group will be placed on an automated insulin delivery system: Tandem t:slim x2 insulin pump with Control IQ technology and Dexcom G6 continuous glucose monitor. They will also be asked to follow a low-carbohydrate diet of 30-40g of carbohydrate per main meal. At baseline they will have a 20-day period of blinded continuous glucose monitoring. Participants in this group will undergo a stepped hyperinsulinaemic hypoglycaemic clamp study at baseline and 8 months. They will also complete quality of life and diabetes treatment questionnaires at baseline and 8 months.
Primary Outcome Measures
NameTimeMethod
The change in plasma glucagon levels (pmol/L) measured during normoglycaemic and hypoglycaemia8 months

Measured at baseline and each glucose plateau in a stepped hyperinsulinaemic hypoglycaemic clamp study at study start and study end

Secondary Outcome Measures
NameTimeMethod
Trial Making Test8 months

Measured during each plateau in a stepped hypoglycaemic clamp study at study entry and study end. Difference in score between plateaus and at trial entry and end.

Time spent above the target glycaemic range (>10mmol/L)8 months

Percentage of time spent above the target glycaemic range

Change in quality of life at trial entry and end.8 months

Measured using the EQ5D-5L- a quality of life questionnaire comprising of five dimensions: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each dimension consists of five levels: no problems, slight problems, moderate problems, severe problems and extreme problems. The participant ticks the box most relevant to them at the time of taking the questionnaire. This response is converted into a 1 digit number and the 5 numbers from a domain can be combined to describe the participant's health state. This questionnaire will be completed at trial entry and then at trial end.

Change in confidence of managing hypoglycaemia8 months

Measured using the Hypoglycaemic Confidence Scale- this is a 9 item scale. The participant rates each item from Not Confident at All to Very Confident. Participants will complete this questionnaire at study entry and study end.

The change in plasma cortisol (nmol/L) levels measured during normoglycaemic and hypoglycaemia8 months

Measured at baseline and each glucose plateau in a stepped hyperinsulinaemic hypoglycaemic clamp study at study start and study end

HbA1c8 months

Difference between baseline and study end

Change in emotional distress related to diabetes at trial entry and end.8 months

Diabetes Distress Scale (DDS-1)- a 28-item self-reporting scale. Each item can be scored from 1 (not a problem) to 6 (a very serious problem). This questionnaire will be completed at study entry and study end.

The change in plasma adrenaline (nmol/L) levels measured during normoglycaemic and hypoglycaemia8 months

Measured at baseline and each glucose plateau in a stepped hyperinsulinaemic hypoglycaemic clamp study at study start and study end

Endogenous glucose production8 months

Measured with stable isotope studies using D2 glucose and D5 glycerol

Attitude to diabetes technologies8 months

Measured using the Diabetes Technology Questionnaire- a 30 item questionnaire. The participant ranks each item from Very Much (1) to Not at all (5). Participants will complete this questionnaire at study entry and study end. Also assessed using the Diabetes Technology Attitudes Survey- a 5 item questionnaire. The participant ranks each item from Strongly Disagree (1) to Strongly Agree (5).

Time in glycaemic range (3.9-10mmol/L)8 months

Percentage time spent in target glycaemic range.

Time spent below the target glycaemic range (<3.9mmol/L)8 months

Percentage of time spent below the target glycaemic range

The change in plasma noradrenaline (nmol/L) levels measured during normoglycaemic and hypoglycaemia8 months

Measured at baseline and each glucose plateau in a stepped hyperinsulinaemic hypoglycaemic clamp study at study start and study end

Digit Span Test8 months

Measured during each plateau in a stepped hypoglycaemic clamp study at study entry and study end. Difference in score between plateaus and at trial entry and end.

Change in fear of hypoglycaemic8 months

Measured using the Hypoglycaemia Fear Survey (HFS)- this survey consists of two subscales- Behaviour and Worry. There are 28 items in the survey that the participant ranks from Never (0) to Almost Always (4). Participants will complete this questionnaire at study entry and study end.

Hypoglycaemia awareness8 months

Measured during each clamp study using the Edinburgh Hypoglycaemic Scale- this is a 17 item scale of symptoms of hypoglycaemia. The participant ranks on a scale from Not at all (1) to A Great Deal (7) whether they are experiencing each symptom at the time of the questionnaire being completed.

Digit Symbol Substitution Test8 months

Measured during each plateau in a stepped hypoglycaemic clamp study at study entry and study end. Difference in score between plateaus and at trial entry and end.

Four Choice Reaction Time Test8 months

Measured during each plateau in a stepped hypoglycaemic clamp study at study entry and study end. Difference in score between plateaus and at trial entry and end.

Trial Locations

Locations (1)

Edinburgh Royal Infirmary/University of Edinburgh

🇬🇧

Edinburgh, United Kingdom

© Copyright 2025. All Rights Reserved by MedPath