MedPath

Effects of neck rotation on left-sided double lumen tube positioning

Not Applicable
Conditions
Differential lung ventilation
Registration Number
JPRN-UMIN000021890
Lead Sponsor
Department of Anesthesia Hyogo Cancer Center
Brief Summary

Twenty six cases resulted 26cases of misplacement into the left double lumen tube into the right bronchus. Optical bronchofiber scope guide corrected 24 of 26cases into the left bronchus. The right sided neck rotation also revealed 24 correct placement of bronchial tube into the left bronchus. The two failed cases were correctly placed by another method respectively. The neck rotation was effective for correct positioning of left double lumen tube as bronchofiber guide, and these two method are suspected as complementary.

Detailed Description

Not available

Recruitment & Eligibility

Status
Complete: follow-up complete
Sex
All
Target Recruitment
20
Inclusion Criteria

Not provided

Exclusion Criteria

none

Study & Design

Study Type
Interventional
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Secondary Outcome Measures
NameTimeMethod