Comparative Analysis of Phase Lag Entropy (PLE) and Bispectral Index (BIS) as an Anesthetic Depth Indicator
- Conditions
- General Anesthesia
- Registration Number
- NCT03424720
- Lead Sponsor
- Hallym University Medical Center
- Brief Summary
The aim of this comparative analysis is to evaluate the reliability of PLE value as an anesthetic depth indicator
- Detailed Description
1. To evaluate the reliability of PLE value as an anesthetic depth indicator, the investigators compare PLE value with BIS score during induction and emergence of general anesthesia using propofol target controlled infusion.
2. In addition, the investigators verify whether or not the facial nerve integrity monitoring affects the efficacy for PLE and BIS values as an anesthetic depth indicator.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 25
- Patients who scheduled for otopharyngeal surgery under facial nerve integrity monitoring requiring general anesthesia and American Society of Anesthesiology (ASA) physical status 1 or 2
- Patient who has been taken anticonvulsant agents, sedatives, and hypnotics
- Patient who has central nerve system disease, neurological disorder
- Patient with hypersensitivity to anesthetics
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Primary Outcome Measures
Name Time Method PLE value during induction and emergence of general anesthesia Through study completion, an average of fifteen months Investigators measure the PLE value as an anesthetic depth indicator before the injection of propofol, at the time point of no response to verbal command, before and after intubation, and at the time point of response to verbal command during emergence of anesthesia.
The PLE value will be reported in a score ranging from 0 (burst suppression or deep sedated) to 100 (full awake).
- Secondary Outcome Measures
Name Time Method BIS value during induction and emergence of general anesthesia Through study completion, an average of fifteen months Investigators measure the BIS value as an anesthetic depth indicator before the injection of propofol, at the time point of no response to verbal command, before and after intubation, and at the time point of response to verbal command during emergence of anesthesia.
The BIS value will be reported in a score ranging from 0 (burst suppression or deep sedated) to 100 (full awake).PLE value during facial nerve integrity monitoring Through study completion, an average of fifteen months Investigators measure the PLE value at the time points of facial nerve integrity monitoring.
The PLE value will be reported in a score ranging from 0 (burst suppression or deep sedated) to 100 (full awake).BIS value during facial nerve integrity monitoring Through study completion, an average of fifteen months Investigators measure the BIS value at the time points of facial nerve integrity monitoring.
The BIS value will be reported in a score ranging from 0 (burst suppression or deep sedated) to 100 (full awake).
Related Research Topics
Explore scientific publications, clinical data analysis, treatment approaches, and expert-compiled information related to the mechanisms and outcomes of this trial. Click any topic for comprehensive research insights.
Trial Locations
- Locations (1)
Hallym University Medical Center
🇰🇷Anyang-si, Gyeonggi-do, Korea, Republic of
Hallym University Medical Center🇰🇷Anyang-si, Gyeonggi-do, Korea, Republic ofKyung Mi Kim, Ph.D.Principal Investigator