Prevalence of Occult Hepatitis B Virus Infection(OBI) in Subjects With Chronic Hepatitis B (CHB) Family History and Cascading of Care Linked to Treatment in West China
试验速览
- 阶段
- 不适用
- 入组人数
- 2,000
- 试验地点
- 1
- 主要终点
- Prevalence of OBI in subjects with CHB family history
研究概览
简要总结
Mother to Child transmission is the main route of hepatitis B virus (HBV) transmission in China, attributing to over 50% HBV infection. Familial aggregation in HBV infection is well recognized with underlying stipulations like mother-to-child transmission(MTCT), susceptible genes, close contact and other factors. Not surprisingly, a large proportion of hepatitis B virus infected population in China have a family history of hepatitis B virus infection. In clinical practice those family members usually undergo merely hepatitis B virus serology tests without HBV DNA test, which ruled out false HBsAg (-) or Occult HBV Infection (OBI) from Screening and linkage to care (SLTC). Unfortunately, the missed-out OBI in CHB family members was of a greater prevalence compared to those from general population (8.0% vs. 2.6%) . Moreover, OBI has been well recognized as strong risk factor in hepatocellular carcinoma (HCC) development with significant HBV DNA integration into host genome . In light of the latest 2019 China CHB guidelines, treatment criteria covered subjects with family history of CHB related cirrhosis or hepatocellular carcinoma(HCC). Therefore, subjects of HBsAg (+) with normal alanine aminotransferase(ALT) or OBI are eligible for further consideration of HBV anti-viral treatment.
This study proposed will explore the prevalence of OBI in subjects with family history of HBV related cirrhosis or HCC. The screened HBsAg (+) with normal alanine aminotransferase(ALT) and OBI subjects would be linked to anti-viral therapies.
详细描述
Serum samples were tested for liver enzymes and liver synthesis function including ALT, aspartate aminotransferase(AST), and albumin, etc. using a Hitachi 7600 automatic analyzer and reagent system (Hitachi, Tokyo, japan). HBsAg quantification was performed using automated electrochemiluminescence Immunoassay (ECLIA) manufactured by Roche. HBsAb, HBeAg, HBeAb and HBcAb were measured semi-quantitatively using Chemiluminescence Immunoassay (CLIA) manufactured by Abbott Diagnostics (USA). Serum HBV DNA levels were measured using the COBAS TaqMan HBV Monitor Test, with a lower limit of detection of 20 IU/mL (100 copies/mL).
The false negative result excluding OBI due to Real time PCR (lower limit of 20 IU/ml) technically may exist. The study group plan to carry out nested PCR (specifically target the HBV Pre-S, S, Pre-C/Core, and X open reading frames) on subjects with HBsAg (-) HBV DNA (-) and HBcAb(+) to double check the potential false negative result in HBV DNA from Real time PCR. Quantitation of intrahepatic HBV cccDNA by quantitative real-time PCR (qPCR).
研究设计
- 研究类型
- Observational
- 观察模型
- Family Based
- 时间视角
- Prospective
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •First- and second-degree relatives of CHB patients in west China;
- •Subjects with family history of CHB related cirrhosis or HCC;
- •Subjects with ability to understand and sign a written informed consent form.
排除标准
- •Positive antibody against hepatitis C virus(HCV),hepatitis D Virus(HDV), or human immunodeficiency virus(HIV) (anti-HCV, anti-HDV, or anti-HIV)
- •Evidence of other autoimmune or metabolic liver diseases (except non-alcoholic fatty liver disease).
- •Moribund state including advanced/pre-terminal liver cancer or other non-hepatic cancers
- •Non-hepatic cancer undergoing chemotherapy within last 6 months
结局指标
主要结局
Prevalence of OBI in subjects with CHB family history
时间窗: 1 year
Serum samples were tested for liver enzymes and liver synthesis function including ALT, Aspartate aminotransferase(AST), and albumin, etc. using a Hitachi 7600 automatic analyzer.HBsAg quantification was performed using automated electrochemiluminescence Immunoassay (ECLIA) manufactured by Roche, with limit of detection at 0.05 IU/mL or confirmed by the HBsAg confirmatory assay ,with limit of detection at 0.005 IU/mL. HBsAb, HBeAg, HBeAb and HBcAb were measured semi-quantitatively using Chemiluminescence Immunoassay (CLIA) manufactured by Abbott Diagnostics (USA). Serum HBV DNA levels were measured using the COBAS TaqMan HBV Monitor Test, with a lower limit of detection of 20 IU/mL (100 copies/mL).
次要结局
未报告次要终点
