跳至主要内容
临床试验/NCT02625194
NCT02625194已完成不适用

The Utility of Oxygen Insufflation During Flexible Fiberoptic Bronchoscope-guided Intubation

Yonsei University1 个研究点 分布在 1 个国家目标入组 36 人开始时间: 2016年1月1日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
不适用
状态
已完成
入组人数
36
试验地点
1
主要终点
Velocity of PaO2 decrease

研究概览

简要总结

This study investigate the utility of continuous oxygen insufflation during fiberoptic bronchoscope-guided intubation.

One group receives oxygen via suction channel of fiberoptic bronchoscope during intubation.

The other group does not receive oxygen during fiberoptic bronchoscope-guided intubation.

Then, the velocity of deoxygenation difference of PaO2(baseline

详细描述

Fiberoptic bronchoscope-guided intubation is a gold standard for intubation of a patient with anticipating difficult airway. This technique takes several minutes without oxygen supply, which results in hypoxia when it prolonged. If continuous supply of oxygen during procedure improve the oxygenation, we can reduce the risk of hypoxemia and increase the safety margin during procedure.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Single (Participant)

入排标准

年龄范围
20 Years 至 60 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • patients who have surgery under general oral endotracheal anesthesia with invasive arterial blood pressure monitoring

排除标准

  • history of lung disease
  • abnormality in chest x-ray
  • anticipating difficult intubation
  • pregnant women
  • who is unable to understand and agree the consent form

研究组 & 干预措施

Oxygen

Experimental

Oxygen is supplied through suction port in bronchoscope during bronchoscope-guided intubation.

干预措施: Oxygen (Drug)

结局指标

主要结局

Velocity of PaO2 decrease

时间窗: from mask removal to 1st manual ventilation after intubation, up to 5 minute

After administration of anesthetic agents and manual ventilation of 5 minutes, arterial blood sampling is collected. Then bronchoscope-guided intubation performed and arterial blood sample is collected immediately after the intubation completed. Time for intubation (between 1st and 2nd blood sample) is recorded. The difference of PaO2(before \& after intubation) is divided by the time taking for intubation.

次要结局

  • visual field(throughout the intubation with bronchoscope, upto 5 minute)
  • success of intubation(300 sec after the beginning of intubation)
  • pH(1. 5 minutes after manual ventilation / 2.right before 1st manual ventilation after intubation, up to 5 minute)
  • PaO2(1. 5 minutes after manual ventilation / 2.right before 1st manual ventilation after intubation, up to 5 minute)
  • PaCO2(1. 5 minutes after manual ventilation / 2.right before 1st manual ventilation after intubation, up to 5 minute)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验