Robotic-assisted Percutaneous Access: Interventional, Non-randomized, Open-label, Non-comparative and First-in-Man Study

NDR Medical Technology Pte Ltd1 site in 1 country5 target enrollmentAugust 7, 2018
ConditionsKidney Stone

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Kidney Stone
Sponsor
NDR Medical Technology Pte Ltd
Enrollment
5
Locations
1
Primary Endpoint
Needle insertion time
Status
Completed
Last Updated
5 years ago

Overview

Brief Summary

This is a first-in-man (FIM) study to show feasibility and safety profile of the newly developed robotic device for percutaneous access in PCNL surgery. Patients with renal stone disease who had standard indications for prone PCNL were included in the study. PCNL was conducted with percutaneous puncture with the aid of robotic device with the use of intra-operative fluoroscopy. 5 patients were recruited in this pilot study over a period of 3 months. Punctures were performed by the board-qualified urologist.

Detailed Description

All patients underwent preoperative investigations and imaging study (CT Urogram/Intravenous Pyelography) done prior to the operation as per standard operation preparation. Intraoperatively fluoroscopic imaging was done for the patients and the images were synchronized to the software. Robotic arm was placed on the site of surgery as for prone PCNL and diaphragm of the arm was centred over the site of desire calyx of entry. A needle was engaged into the centre of the diaphragm and using the software the need was aligned in the line of puncture automatically based on the fluoroscopic images. After the alignment was done the needle was advanced manually by the surgeon until the entry was confirmed by efflux of urine from the puncture needle. After the entry was confirmed a standard PCNL using 24 F or 30 F Balloon dilator was performed and stone cleared using Cyberwand/ Shockpulse etc. All the intraoperative and perioperative parameters as mentioned in the data collection form was measured. Results was analysed with the main focus on time of obtaining the puncture, accuracy of puncture, radiation exposure time till calyceal entry which was confirmed by free flow of urine and for any complications. Patients aged between 21 to 75 years old who were diagnosed with kidney stone diseas and planned for prone PCNL with indication for surgery as per standard of care were recruited. They understood the purpose of testing and offered their voluntary and informed consent. The robotic device i.e. ANT lesses the learning curve of percutaneous access as it reduces the need for surgeon's visualization of the calyceal system and the needle alignment. It also improved efficiency as there is less dependence on human skills during the procedure. As a whole, the FIM trial was a success. The performance of the ANT system during the trial was satisfactory. The robot alignment time is less than 30 seconds. Total puncture time was around 6 minutes and no AEs were reported.

Registry
clinicaltrials.gov
Start Date
August 7, 2018
End Date
November 1, 2018
Last Updated
5 years ago
Study Type
Interventional
Study Design
Single Group
Sex
All

Investigators

Sponsor
NDR Medical Technology Pte Ltd
Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • Age between 21 to 75 years
  • Diagnosed with kidney stone disease and planned for prone PCNL with indication for surgery as per standard of care
  • Subject who understand the purpose of testing, voluntary and informed consent, patients undergoing invasive imaging follow-up.

Exclusion Criteria

  • Bleeding disorders
  • Patient on anticoagulation/antiplatelets drugs
  • Pyonephrosis
  • Pregnant women
  • Not able to have prone position for the procedure due to comorbidities
  • Moderate to severe renal failure
  • The patient's life expectancy is less than 12 months
  • Poor compliance and patients unable to complete the study in accordance with the requirements.

Outcomes

Primary Outcomes

Needle insertion time

Time Frame: During procedure

Time taken for PCNL procedure

Needle alignment time

Time Frame: During procedure

Time taken for needle alignment

Radiation dosage from placement of robot to efflux of urine

Time Frame: During procedure

A measure of the radiation exposed during the surgical procedure

Time to target

Time Frame: During procedure

Time taken for the needle to reach the calyx, from on the skin to successful needle targeting

Radiation dosage from placement of robot to successful needle target via image confirmation

Time Frame: During procedure

A measure of the radiation exposed during the surgical procedure

Number of needle insertion attempts to obtain access

Time Frame: During procedure

Number of attempts before successfully reaching the calyx

Study Sites (1)

Loading locations...

Similar Trials