Skip to main content
Clinical Trials/NCT05573139
NCT05573139
Completed
Not Applicable

Reliability and Validation of New Manual Dynamometer to Measure Lower Limb Strength: Clinical Study

Faculdade de Ciências Médicas da Santa Casa de São Paulo1 site in 1 country26 target enrollmentMarch 20, 2021

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Muscle Strength
Sponsor
Faculdade de Ciências Médicas da Santa Casa de São Paulo
Enrollment
26
Locations
1
Primary Endpoint
Muscle strength assessment by hand dynamometer of the knee
Status
Completed
Last Updated
3 years ago

Overview

Brief Summary

INTRODUCTION: There are several ways to assess muscle strength: not only subjective ways, but also high standard equipment, such as isokinetic dynamometers. These, however, are expensive, and require extensive training. Over the years, manual dynamometers were produced, portable equipment that simplify its use. Among them, a national equipment was developed, but its reliability and validation are yet to be confirmed, compared to equipment already used, such as the Lafayette®. OBJECTIVE: Assess the reliability of a new manual dynamometer - Medeor® device (SP Tech model) -, in relation to the gold standard, Lafayette® device (model 01165), already validated, in the evaluation of muscle strength of the knee and hip groups. METHODS: A total of 26 recruits of both sexes were selected. Muscle strength was measured by Lafayette® and Medeor® dynamometers in the following groups: knee flexors and extensors; flexors, extensors, abductors, adductors, hips internal and external rotators. Each data was collected 3 times, and then the average was calculated.

Detailed Description

Keywords: Muscle Strength; Muscle Strength Dynamometer; Lower Extremity.

Registry
clinicaltrials.gov
Start Date
March 20, 2021
End Date
December 20, 2021
Last Updated
3 years ago
Study Type
Interventional
Study Design
Single Group
Sex
All

Investigators

Sponsor
Faculdade de Ciências Médicas da Santa Casa de São Paulo
Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • 20-40 year

Exclusion Criteria

  • individual who practiced physical activity,
  • cognitive disability
  • osteomioarticular diseases in lower limb and/or spine
  • rheumatic or cardiorespiratory disease

Outcomes

Primary Outcomes

Muscle strength assessment by hand dynamometer of the knee

Time Frame: 1 day (single assessment)

Assessment of muscle strength by hand dynamometer of the knee

Muscle strength assessment by hand dynamometer of the hip

Time Frame: 1 day (single assessment)

Assessment of muscle strength by hand dynamometer of the hip

Study Sites (1)

Loading locations...

Similar Trials