NCLE-Cone-beam CT Navigation Bronchoscopy
- Conditions
- Peripheral Lung Parenchyma TumorLung CancerLung Neoplasm
- Interventions
- Device: needle-based confocal laser endomicroscopy
- Registration Number
- NCT06505642
- Brief Summary
The goal of this proof of principle observational study is to investigate in patients with suspected peripheral pulmonary nodules. The main question it aims to answer is:
• What is the concordance between CBCT navigation success (tool-in-lesion on CBCT spin) and nCLE tool-in-lesion confirmation (tool-in-lesion nCLE criteria observed).
Participants scheduled to undergo a diagnostic conebeam navigation bronchoscopy will be included in the study. nCLE imaging at the tip of the TBNA needle will be added to the procedure for study purposes.
Two needle punctures of the pulmonary nodule will be followed by nCLE imaging directly followed by a tool-in-lesion CBCT spin in order to compare nCLE results with CBCT results.
- Detailed Description
Lung cancer remains a significant problem in current society with one of the higher cancer related mortality rates. The increased use of chest computed tomography (CT) and the po-tential future lung cancer screening result in an increased detection of early-stage peripheral lung cancer. Bronchoscopies are often indicated to collect tissue for diagnosis and to aid treatment decision making.
Diagnostic bronchoscopy for peripheral lung nodules remains challenging despite many tech-nological innovations. The procedure comprises three essential pillars needed for a diagnos-tic success: navigation to the lesion, tool-in-lesion confirmation and adequate tissue retrieval.
Cone beam computed tomography navigation bronchoscopy (CBCT-NB) is a fairly new tech-nique that provides coarse navigation to the pulmonary lesion with real-time guidance using augmented fluoroscopy (AF). An initial CBCT scan allows for segmentation of the target le-sion and selecting the optimal pathway. Repeated CBCT scanning allows for confirmation that the target has been reached (navigation success) or if repositioning is needed.
Although the technique is very promising, an often discussed disadvantage of CBCT is the inherent use of ionizing radiation, limited availability and challenges with small nodules lo-cated in the basal and posterior fields due to respiratory motion. Most procedures ask for multiple CBCT spins both for trajectory planning, tool adjustments and tool-in-lesion confir-mation. This, combined with extensive use of fluoroscopy is associated with radiation expo-sure for both patients and the investigation team. Additionally, CBCT-NB with AF provides information from a global perspective rather than a local perspective. In experienced centers, coarse navigation guidance seems of lesser concern and fine positioning and optimal tissue sampling are the biggest problems to be overcome. The persistently low diagnostic yield of navigation bronchoscopies can for the majority be attributed mispositioning of the tools in "the last centimeter". Therefore there is a need for complementary techniques providing real-time information for fine-tuning the needle position such as needle-based confocal laser en-domicroscopy (nCLE) also called the "smart needle".
Confocal laser endomicroscopy (CLE) is a high-resolution microscopic technique that visual-izes individual cells in real-time at the tip of the biopsy needle, allowing for real-time micro-scopic feedback for fine tuning needle positioning and tool-in-lesion confirmation. Currently, it is unknown which (combination of) techniques are the most optimal (i.e., leading to a high di-agnostic yield and cost-effective). Therefore, research is needed to investigate the potential of new (combinations of) techniques. To date, there are no reports on the combination of CBCT-NB with nCLE.
Objective: This study aims to investigate proof of principle of utilizing nCLE during CBCT-NB navigation bronchoscopy. A confirmatory CBCT spin is considered the gold standard for tool-in-lesion but is associated with additional radiation exposure. The aim is to investigate the concordance between CBCT navigation success (tool-in-lesion on CBCT spin) and nCLE tool-in-lesion confirmation (tool-in-lesion nCLE criteria observed). The investigators also hypothesize that nCLE could reduce or replace the need for additional confirmatory CBCT scans and limit fluoroscopy use.
Study design: Investigator-initiated proof of principle medical device study
Study population: Patients (18 years and older) with (suspected) pulmonary nodules with an indication for cone-beam computed tomography navigation bronchoscopy.
Procedure: Cone beam computed tomography navigation bronchoscopy combined with needle-based confocal laser endomicroscopy.
Main study parameters/endpoints:
* CBCT-NB navigation success as either tool-in-lesion OR unsuccessful
* nCLE tool-in-lesion confirmation, defined as tool-in-lesion nCLE criteria observed
Recruitment & Eligibility
- Status
- RECRUITING
- Sex
- All
- Target Recruitment
- 25
- 18 years or older
- Suspected pulmonary nodule with an indication for CBCT-NB (decided by multidisciplinary tumour board)
- Nodule must be solid or partially solid
- Solid part of the nodule must be at least 8 mm
- Largest dimension of the nodule on CT equal or less than 30 mm
- Ability to understand and willingness to sign a written informed consent
- Inability or non-willingness to provide informed consent
- Patients with an endobronchial visible lung tumor on bronchoscopic inspection
- Patients in which the target lesion is within reach of the linear EBUS scope
- Lung nodules that resolved at the time of index intraprocedural CBCT
- Failure to comply with the study protocol
- Patients with known allergy for fluorescein or risk factors for an allergic reaction
- Pregnant or breastfeeding women
- Patients with hemodynamic instability
- Patients with refractory hypoxemia
- Patients with a therapeutic anticoagulant that cannot be held for an appropriate in-terval before the procedure
- Patients who are unable to tolerate general anesthesia according to the anesthesiologist
- Patient undergoing chemotherapy as several chemotherapies have fluorescent properties at the same wavelength (e.g. doxorubicin)
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description nCLE + CBCT-NB needle-based confocal laser endomicroscopy Patients with a suspected malignant peripheral pulmonary nodule(s) referred for cone beam ct navigation bronchoscopy for tissue sampling.
- Primary Outcome Measures
Name Time Method CBCT navigation success and nCLE tool-in-lesion confirmation Intra-procedure CBCT-NB navigation success: tool-in-lesion OR unsuccessful navigation nCLE tool-in-lesion confirmation: in-lesion nCLE criteria seen
- Secondary Outcome Measures
Name Time Method Interobserver agreement (IOA) and intraobserver reliability (IOR) Intra-procedure Interobserver agreement (IOA) represented by the Cohen's kappa statistics (mean with 95% confidence intervall) and intraobserver reliability (IOR) represented by the Cohen's kappa statistics (mean +/- standard deviation)
Sensitivity, specificity and accuracy of post-procedure nCLE image assessment Intra-procedure Sensitivity, specificity and accuracy of post-procedure nCLE image assessment described as percentages.
Technical feasibility Intra-procedure Proportion of nCLE imaging that are successful (meaning that the preloaded needle can be advanced through the working channel, puncture the nodule, advance the CLE probe and start imaging) resulting good quality images.
Safety Up to 7 days post procedure Number and proportion of (severe) adverse events ((S)AEs) and investigational procedure related adverse events (AEs)
Sensitivity, specificity and accuracy of real-time nCLE imaging assessment Intra-procedure Sensitivity, specificity and accuracy of real-time nCLE imaging assessment all described in percentages.
Diagnostic yield up to 6 months post procedure Proportion (expressed in percentages) of patients in whom the bronchoscopic procedure results in a definitive diagnosis out of the total number of patients that have received the diagnostic bronchoscopic procedure.
Diagnostic sensitivity for malignancy up to 6 months post procedure Proportion (expressed in percentages) of patients that have malignancy diagnosed by bronchoscopic tissue sampling, relative to the total number of patients with a final diagnosis of malignancy as determined by the reference standard.
Trial Locations
- Locations (1)
Amsterdam UMC
🇳🇱Amsterdam, Netherlands