MedPath

Predicting Success With Hearing Aids

Completed
Conditions
Presbycusis
Hearing Loss
Registration Number
NCT00371449
Lead Sponsor
US Department of Veterans Affairs
Brief Summary

The primary complaint of individuals with hearing loss is difficulty understanding speech in the presence of background noise. Although hearing aids help individuals understand speech in background noise better, there is a high rate of hearing aid rejection in part due to continued difficulty understanding speech in complex listening situations. The results of this study may demonstrate that speech-in-noise test results can be a predictor of hearing aid success. The results of this study also may lead to further studies that can evaluate interventions to improve hearing aid success for individuals who are identified as unsuccessful hearing aid users.

Detailed Description

As numerous studies have reported, the most common complaint that individuals with sensorineural hearing loss have about their hearing is that they can hear speech but they cannot understand speech, especially in background noise. For this type of hearing loss and most other types of hearing losses, hearing aids are the intervention of choice. The majority of individuals who receive hearing aids are successful hearing-aid users in that both subjectively and objectively they function better with their hearing aids than without hearing aids. Other individuals are unsuccessful hearing-aid users because for a variety of reasons their perception is that the hearing aids do not enable them to function better. Two studies (Popelka et al., 1998; Kockchin, 2000) indicate that about 25% of individuals who receive hearing aids can be considered unsuccessful hearing-aid users. If potentially (un)successful hearing-aid users can be identified, then audiologic rehabilitation programs can be designed for use with potentially successful hearing-aid users and more extensive audiologic rehabilitation programs can be designed for use with those individuals who are potentially unsuccessful hearing-aid users.

Data from a recent series of studies by N b lek and her colleagues (1991, 2004) indicate that successful and unsuccessful hearing-aids users can be predicted based on their performance on a subjective speech-in-noise task in which a most comfortable listening level is established for a travelogue story and the level of a multitalker babble is established that permits following the travelogue. The difference between these two levels is the acceptable noise level (ANL). Based on the ANL data, N b lek et al. (2006) report with 85% confidence those individuals who are successful hearing-aid users and those who are unsuccessful hearing-aid users. One premise of this proposal is that the ANL is in fact an estimate in the subjective realm of the signal-to-noise (S/N) at which the listener is comfortable listening to a speech signal in background noise.

Recently in our laboratory the words-in-noise (WIN) test was developed that involves the presentation of words in multitalker babble at signal-to-babble (S/B) ratios from 24- to 0-dB in 4-dB decrements. The 50% point on the function is calculated with the Spearman-K rber equation. This objective instrument provides an average 8-dB separation in recognition performances between listeners with normal hearing and listeners with hearing loss. The 50% points for the listeners with normal hearing are 0- and 6-dB S/B, whereas the 50% points for the listeners with hearing loss are 8- and 16-dB S/B. Thus, not only is the WIN very sensitive to the effects of hearing loss on speech understanding, but the WIN provides a range of performances by listeners with hearing loss.

The proposed study is designed to answer the following two key questions:

1. What is the relationship between ANL performance (subjective paradigm) and WIN performance (objective paradigm) in both unaided and aided conditions?

2. How well do the ANL and WIN scores predict subjective hearing-aid outcome domains (use, satisfaction, benefit, and global)?

In addition, the study design enables multiple comparisons to be made among several of the study variables and among many traditional variables such as age, pure-tone thresholds, and word-recognition abilities in quiet.

Future goals beyond this proposal involve the development (1) of systematic protocols to select amplification devices or specific features for amplification based on WIN or ANL performance, and (2) of audiologic rehabilitation programs that can be administered quickly and effectively (depending on the category of hearing-aid success that was determined from performances on the WIN or ANL) to veterans who are receiving hearing aids.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
120
Inclusion Criteria
  • adult onset of hearing loss,
  • symmetrical, sensorineural hearing loss,
  • no more than 60 dB HL hearing loss measured via an average of air conduction thresholds at .5, 1, and 2 kHz in each ear, and
  • use of binaural hearing aids of the same make and model for each ear
  • at least 3 months of hearing aid use.
Exclusion Criteria
  • enrollment in group audiologic rehabilitation classes,
  • currently using an FM system,
  • inability to read and write American English, and
  • signs of middle ear or retrocochlear pathology.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Words-in-noise Testaided (after wearing hearing aids for at least 3 months)

The WIN consists of two lists of 35 Northwestern University Auditory Test No. 6 words (NU-6; Tillman and Carhart, 1966) presented in a 6-talker babble at 7 SNRs ranging from 24- to 0-dB in 4-dB decrements. Thus for each list, five unique words spoken by a female talker are presented at each SNR with the level of the babble fixed (Department of Veterans Affairs, 2006). The SNR at which the 50% point occurs is calculated with the Spearman-Kärber equation (Finney, 1952). Normal performance on the WIN is between 0 and 6-dB S/N.

Secondary Outcome Measures
NameTimeMethod
Measure of Audiologic Rehabilitation Self-Efficacy for Hearing Aids (MARS-HA)aided (after wearing hearing aids for at least 3 months)

Measures hearing-aid self-efficacy over four subscales (basic handling, advanced handling, adjustment, and aided listening). Subscale scores are averaged to produce a total self-efficacy scores that can range from 0 (low self-efficacy) to 100 (high self-efficacy).

Acceptable Noise Level Testaided (after wearing hearing aids for at least 3 months)

The ANL consists of a speech signal and a competing noise signal. The speech signal is a continuous monologue (Arizona Travelogue) by a male talker and the competing noise signal is the 12-talker babble from the Speech in Noise (SPIN) test (Kalikow et al, 1977). The speech and babble stimuli are recorded on separate channels on a compact disc (CD; Cosmos, Inc.). The task of the listener was to adjust the level of the travelogue to the most comfortable level (MCL) and then to adjust the level of the babble to the level the listener is willing "to put up with" and still follow the travelogue, or to the background noise level (BNL). The ANL (in dB) is the difference between the MCL and BNL.

Satisfaction With Amplification in Daily Life (SADL)aided (after wearing hearing aids for at least 3 months)

Measures how satisfied listeners are with their current hearing aids. Total scale scores are computed by averaging the subscale (positive effect, negative features, personal image, and service \& delivery) scores that range from 1 (no satisfaction) to 7 (high satisfaction).

International Outcomes Inventory for Hearing Aids (IOI-HA)aided (after wearing hearing aids for at least 3 months)

Overall/general hearing-aid outcome measure. Range in scores are 7-35 with higher scores representing better outcomes.

Speech Spatial and Qualities of Hearing Scale (SSQ)aided (after wearing hearing aids for at least 3 months)

The SSQ measures hearing abilities related to speech, spatial perception, and quality of sound using a 1-10 scale. Items are averaged across the test. Higher scores indicate better outcomes.

Trial Locations

Locations (1)

James H. Quillen VA Medical Center

🇺🇸

Mountain Home, Tennessee, United States

© Copyright 2025. All Rights Reserved by MedPath