MedPath

Effect of Snapshot Freeze on Cardiac CT Image Quality

Not Applicable
Completed
Conditions
Heart Diseases
Interventions
Other: non-seloken
Registration Number
NCT02618473
Lead Sponsor
Odense University Hospital
Brief Summary

The aim of this study was to investigate the effect of a new motion correction algorithm on image quality and diagnostic utility in unselected patients undergoing coronary cardiac computed tomography, and to investigate if this motion correction algorithm can compensate for the usual use of intravenously medication (beta-blockers) before the scan.

Detailed Description

Aims:

To investigate the motion correction algorithm Snapshot-Freeze(SSF) compared to standard reconstruction(STD) in patients randomized to receive beta-blockers(BB) or no beta-blockers(non-BB) before coronary CT angiography (CCTA), and to investigate if SSF can replace BB.

Methods:

The study included 140 consecutively recruited patients scheduled to CCTA to rule out coronary artery disease.

The inclusion criteria were: age ≥ 18 years, Glomerular filtration rate ≥ 60 mL/min, Heart Rate between 60 and 85 bpm before the scan. The exclusion criteria were: irregular heart rhythm or history of allergic reaction to contrast agents. Patients were randomized to the BB group or the non-BB group. The trial complied with the Declaration of Helsinki and was approved by the local ethics committee. Written informed consent was obtained from all patients.

Image quality score:

The evaluation was performed according to the Likert score as follows: 1: excellent, no motion artifacts, clear delineation of the segments; 2: good, minor artifacts, mild blurring of the segment; 3: adequate, moderate artifacts, moderate blurring without structure discontinuity; and 4: poor and non-diagnostic, with doubling or discontinuity in the course of the segments, preventing evaluation or producing vessel structures that were not differentiable. In cases where the image quality was less than excellent (Likert score 2-4), the readers noted the reason(s) for the observed artifact.

Statistical analyses:

Quantitative variables were expressed as mean ± standard deviation, and categorical values as frequencies or percentages. Values from the Likert score were dichotomized to excellent vs. non-excellent (Likert score 1 vs. 2-4), and diagnostic vs. non-diagnostic (Likert score 1-3 vs. 4). McNemar's test was performed to test categorical variables separately per-vessel and per-patient level. Analyses for all segments were calculated by the Wilcoxon signed-rank test.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
140
Inclusion Criteria
  • age ≥ 18 years,
  • glomerular filtration rate ≥ 60 mL/min,
  • heart rate between 60 and 85 bpm before the scan
Read More
Exclusion Criteria
  • irregular heart rhythm
  • history of allergic reaction to contrast agents
Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
non-selokennon-selokenPatients randomized to "non-seloken", do not receive any medication.
Primary Outcome Measures
NameTimeMethod
images with non diagnostic image qualityup to 1 year

number of non diagnostic images.

Secondary Outcome Measures
NameTimeMethod
images with Excellent image qualityup to 1 year

number of presented images with "Excellent" image quality

motion artifactsup to 1 year

number of presented motion artifacts

Trial Locations

Locations (1)

Department of Medical Research, OUH, Svendborg

🇩🇰

Svendborg, Denmark