MedPath

Pilot Study to Investigate the Creation of Physiological Rhythm by Closed Loop Stimulation in hEart Failure pAtients With chronoTropic incompEtence

Not Applicable
Completed
Conditions
Heart Failure
CPX
Interventions
Device: Cardiac Resynchronization therapy device with Closed Loop Stimulation (CLS)
Registration Number
NCT03157076
Lead Sponsor
Biotronik SE & Co. KG
Brief Summary

The study assesses the effect of Closed Loop Stimulation (CLS) on the ventilatory efficiency slope and estimates the patient responder rate to CLS in patients with severe chronotropic incompetence treated with a cardiac resynchronization therapy (CRT) device.

Detailed Description

In patients with pharmacological refractory heart failure (HF), systolic dysfunction, and cardiac dyssynchrony, the cardiac resynchronization therapy (CRT) reduces the risk of death, and improves symptoms and quality of life.

A considerable portion (80%) of patients with a CRT indication has a chronotropic incompetence (CI). CI usually induces a stress intolerance which negatively affects the quality of life. In addition of being a marker of diminished exercise capacity, severe CI (sCI) may be an independent predictor of mortality.

The sensor-based rate adaption provided by the implanted CRT device delivers a possible therapeutic approach for the CI.

Usually, rate adaption is achieved by an accelerometer. The previous studies in terms of effectiveness of rate adaption in CRT patients with CI showed inconsistent results.

In addition to an accelerometer to deliver the rate adaption BIOTRONIK provides closed loop stimulation (CLS) as unique feature in a CRT device. CLS determines the appropriate heart rate based on intra-cardiac impedance measurements. These measurements reflect changes of the cardiac contraction dynamics in reaction to information coming from the autonomic nervous system. CLS takes the information on the contraction dynamics and translates it into an adequate heart rate adaptation, thus delivering physiologically appropriate therapy.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
30
Inclusion Criteria
  • CRT class I indication at time of implantation, according to current guidelines
  • Implantation of CRT-device including CLS > 6 months prior to enrollment
  • Stable heart failure status for at least 1 month
  • Optimal cardiovascular drug treatment according to current guidelines
  • NYHA class II or III
  • Patient is able to comply with the protocol
  • Patient provided written informed consent
  • Stable location of residence
Exclusion Criteria
  • Planned cardiovascular intervention within the next 3 months
  • Admission for decompensated heart failure or acute coronary syndrome in the preceding 3 months
  • Ongoing symptoms of myocardial ischemia
  • Known persistent, long-standing persistent or permanent atrial fibrillation
  • COPD with GOLD ≥ 3
  • Planned absence of residence for more than one week during study period
  • Pregnant or breast-feeding women
  • Participation in another interventional clinical investigation
  • Age < 18 years
  • Placed in an institution due to official decree or judicial order
  • Dependent from the sponsor, the clinical site or the investigators

Study & Design

Study Type
INTERVENTIONAL
Study Design
CROSSOVER
Arm && Interventions
GroupInterventionDescription
Intrinsic modeCardiac Resynchronization therapy device with Closed Loop Stimulation (CLS)-
Pacing mode with CLSCardiac Resynchronization therapy device with Closed Loop Stimulation (CLS)-
Primary Outcome Measures
NameTimeMethod
Ventilatory efficiency slope2 months

The slope of VE/VCO2 describes the ventilatory efficiency during effort, showing the amount of air that must be ventilated to eliminate 1 litre of CO2.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Charité Universitätsklinikum - Campus Benjamin Franklin

🇩🇪

Berlin, Germany

© Copyright 2025. All Rights Reserved by MedPath