The Colon Endoscopic Bubble Scale (CEBuS); Validation Study
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 24
- 试验地点
- 1
- 主要终点
- Reliability and reproducibility validation of the Colon Endoscopic Bubble Scale (CEBuS)
研究概览
简要总结
Colonoscopy is currently accepted as the gold standard in screening, surveillance and prevention for colorectal cancer (CRC), and therefore, its quality is a major priority.
The quality of colonoscopy is greatly dependent on the quality of the bowel preparation, which can be limited by stool, foam, bubbles and other debris. In fact, colonic bubbles are described in 30 to 40% of colonoscopies, possibly undermining the quality of the exam, impairing the endoscopists view, demanding the further use of water or simethicone and eventually increasing fatigue and costs, while diminishing diagnostic accuracy.
Although previous attempts, to date no endoscopic scale is validated regarding the presence of bubbles and most widely accepted and already validated scales do not include the presence or absence of bubbles in their definition, leading to the use of different home-made scales in randomized trials and impairing any solid meta-analysis conclusion. As so, the goal of this study is to develop and validate a new colonic bubble score (Colon Endoscopic Bubble Scale - CEBuS).
详细描述
Colonoscopy bowel preparation quality is a major concern since inadequate bowel preparation can reach levels as high as 30% which lead to several guidelines in this area, with the recent recommendation of at least 90% of good bowel preparations for all colonoscopies. In fact colonic mucosal visualization can be limited by residual stool, bubbles, bile and other debris increasing the risk of missing lesions.
Around 30 to 40% of the exams can have bubbles increasing the risk of missing lesions and in the other hand increasing the time of the exam, generating more fatigue in the endoscopist and increasing the costs.
The influence of colon bubbles in bowel preparation and strategies to solve them, for example with the use of simethicone in the bowel preparation, were addresses in recent studies, summarized in a 2018 meta-analysis recommending the use of simethicone in the bowel preparation scheme.
Current recommendations advise the use of validated scales to evaluate bowel preparation quality, but the three major validated scales, Boston, Ottawa and Aronchick, does not address the problem of graduation of colonic bubbles and possible actions to undertake regarding the severity of the bubbles concentration. The advent of multiple randomized trials addressing the use of simethicone in the bowel preparation to reduce or eliminate bubble formation lead to attempts to design scales to graduate the concentration of bubbles in the colon.
To date suggested scales are heterogeneous regarding the graduation (3 to 4 levels), defining criteria for each level with some based on percentage of colonic circumference obscured by bubbles to the amount of bubbles that could lead to miss a polyp of 5 or 10 millimetres.Two recently published studies on the influence of simethicone on bowel preparation tried to validate a colonic bubble scale, based on previous suggested and non-validated scales, although with only fair to moderate inter-observer variability.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Cross Sectional
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •For the expert group: at least 15 years of regular practice in colonoscopy
- •For the trainee group: 5 years or less in the practice of colonoscopy
排除标准
- •Non endoscopist and if out of the experience standards required.
结局指标
主要结局
Reliability and reproducibility validation of the Colon Endoscopic Bubble Scale (CEBuS)
时间窗: 1 month
Evaluate the Intraclass correlation coefficients (ICC) and Fleiss kappa test The Colon Endoscopic Bubble Scale (CEBuS) was designed with a 3 grades scale: CEBuS-0 - no or minimal amount of bubbles, covering less than 5% of the surface, not relevant for adequate mucosa visibility (better outcome) CEBuS-1 - moderate amount of bubbles, covering between 5% and 50% of the surface, affecting mucosa visibility and requiring additional time for removal CEBuS-2 - severe amount of bubbles, covering more than 50% of the surface, obscuring mucosa visibility and requiring additional time for removal (worse outcome)
次要结局
- Influence of experience in the Colon Endoscopic Bubble Scale (CEBuS)(1 month)
- Evaluation of the clinical attitude(1 month)
研究者
Filipe Taveira
Principal Investigator
Portuguese Oncology Institute, Coimbra