MRI and Orbital Tumours (MEDORT)
- Conditions
- Orbital TumorOrbital Pseudotumor
- Registration Number
- NCT02401906
- Lead Sponsor
- Fondation Ophtalmologique Adolphe de Rothschild
- Brief Summary
Orbital masses develop at the expense of the orbital structures lacrimal glands, oculomotor muscles, optic nerve, meningeal spaces, peripheral nerves, bone wall, orbital fat, lymphoid structures or vascular structures. These masses can be tumors, benign or malignant, or pseudotumor, mainly represented by specific or non-specific orbital inflammation.
Pathology is of considerable importance for the diagnosis and the treatment of those masses. However, biopsy or surgical resection of the orbital masses is sometimes difficult and dangerous outside expert centers.
The identification of a non-invasive technique for distinguishing tumors from pseudotumors, thus avoid in some cases a biopsy, would be a major contribution for the patients.
The MRI assessment performed routinely in a patient with an orbital mass includes morphological sequences T1, T2 fat suppression, T1 injected fat suppression, diffusion. This exploration requires, regardless of the performed research, a contrast agent injection (0.1 mg / kg weight of Gadobutrol®).
In this research protocol, during the injection of the contrast agent performed during the MRI assessment performed routinely, a DCE perfusion sequence, which consists of a repeated acquisition at short intervals of a volume gradient echo T1, will be added. This acquisition will be preceded by two short series for calibration. The post treatment will include parametric permeability cards (Ktrans) and plasmatic volume (Vp), evaluating one or more regions of interest in the tumor, normal lacrimal glands, jaw muscles and nasal mucosa being the reference. It will also be added a magnetic susceptibility EPI sequence type. All the qualitative parameters (T1, T2, T1 injected, distribution, low signal intensity in susceptibility) and quantitative (Ktrans, Vp, relative intensity enhancement, apparent diffusion coefficient) parameters will be collected.
The result of the pathological exam of the biopsy or of the surgical specimen, which is the gold-standard, will be collected.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 200
- Patient aged over 18 years, with an orbital mass for which a biopsy or a resection is planned, coming for an MRI, before any surgical treatment
- Absolute or relative contra-indication to MRI or to a contrast agent gadolinium injection (including pregnant or likely to be, breastfeeding women)
- Patient under guardianship
- Patient not willing to participate.
- Lack of affiliation to social security or medical state aid (AME) or universal health coverage (CMU)
- Motion artifact on the sequences, not corrected by the repeat sequences
- Metal artifact prohibiting the analysis of the region of interest
- Biopsy or resection not performed, particularly if the orbital mass is due to an infection
- MRI findings allowing a diagnosis without the need for pathology
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Sensitivity and specificity based on the patterns of the intra voxel incoherent motion, the dynamic susceptibility contrast and enhancement, for distinguishing orbital tumors from orbital pseudotumor, the gold standard being the pathological exam. 1 month
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Fondation ophtalmique Adolphe de Rothschild
🇫🇷Paris, France