Early Identification of Metabolic Function Derangements Such as Diabetes, Liver, Renal Issues by Respyr Smart Breath Analyzer and Its Validation as a Screening Tool Among Diseased and Healthy Controls
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 3,000
- 试验地点
- 1
研究概览
简要总结
This is a prospective, multicentric, non-treatment study to build and validate a portable, non-invasive smart breath analyzer that can screen underlying health issues using exhaled breath. The study will be conducted with healthy participants and participants with known cases of diabetes, kidney related issues, liver related issues, and lung related issues as confirmed by pathology reports. In phase 1, 500 apparently healthy individuals with normal levels of fasting and postprandial blood sugar, renal function test, liver function test, and lung function test will be recruited. In phase 2, 500 patients of type 2 diabetes, liver function, renal function, and lung function derangements each diagnosed by 10% increment above normal values will be enrolled. In phase 3, validation of the breath analyzer as a screening tool for early identification of type 2 diabetes, liver, renal, lung and other metabolic function derangements will be done by randomly assigning healthy and diseased participants for exhaled breath sample analysis. The study is based on the principle of exhaled breath analysis where parts per million and parts per billion level of volatile organic compounds and gases in human breath will be measured. AI based algorithms will be generated to effectively screen unhealthy biomarker levels, enabling timely preventive action.
详细描述
The smart breath analyzer, Respyr is an IoT and deep-tech enabled portable device developed by Humors Tech Pvt Ltd, Bangalore, India. The device measures volatile organic compounds (VOCs) and gases at parts-per-million and parts-per-billion levels in exhaled breath using AI and ML-based algorithms to identify metabolic derangements non-invasively.
Registration Details:
The study is registered with CTRI (CTRI/2022/09/045983) and ethics approval has been obtained from the Institutional Ethics Committee of JSS Medical College, Mysore (Ref: JSSMC/IEC/260822/07/CT Final Approval/2022-23, dated 19.12.2022). Protocol number: HTB-PROTOCOL-01, Version 1, dated 07 March 2022.
Testing Procedure:
Participants will provide an exhaled breath sample under fasting conditions, or with a minimum gap of 1 hour after consuming water and 3-4 hours after consuming food. The breath analyzer readings will be compared against standard laboratory diagnostic values including FBS/RBS, RFT, LFT, spirometry, and lipid profile, all tested within 15 days of participation.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Control
- 时间视角
- Cross Sectional
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Participant must either be a completely healthy individual as confirmed by blood examination, or a known case of diabetes, kidney disease, liver disease, and lung disease with relevant diagnostic reports tested within 15 days of participation
- •All genders and ethnicities
- •Age 18 to 75 years
- •Participant who has given informed consent
- •Participant must be fully vaccinated for COVID-19
- •Participant must use the smart breath analyzer at fasting condition; if not fasting, minimum gap of 1 hour after water and 3-4 hours after food
排除标准
- •Individual less than 18 or above 75 years of age
- •Pregnant and lactating females
- •Known case of ongoing illness such as Cancer, AIDS, COVID-19, Cough, Fever, TB, Chickenpox, Influenza, Mumps, or Tonsillitis
- •Individual who has not given informed consent
