Corneal Sensitivity in Silicone Hydrogel Contact Lens Wear
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 42
- 试验地点
- 2
- 主要终点
- Difference in corneal sensitivity threshold baseline and after one and six weeks of daily contact lens wear
研究概览
简要总结
Soft contact lenses can affect the ocular surface and sometimes cause intolerance. The aim of this study is to measure corneal sensitivity using the Swiss Liquid Jet aesthesiometer at baseline, after one and after six weeks, in novice daily contact lens wearers.
详细描述
Contact lens discomfort is described by many wearers. Wearing contact lenses can influence corneal sensitivity through three mechanisms: hypoxic, mechanical and inflammatory. A change in corneal sensitivity can be considered an indicator of a change in corneal physiology. Corneal sensitivity plays a major role in maintaining eye health. The interest of this study is to test the variability of the corneal sensitivity threshold during a new adaptation of silicone hydrogel contact lenses, and to verify whether there is a correlation with the wearer's comfort. For that, corneal sensitivity threshold measurements are taken at the baseline and then after one and six weeks of daily contact lens wear. The measurement is performed with the Swiss Liquid Jet aesthesiometer for corneal sensitivity (SLACS). After one week and six weeks of daily lens wear, participants complete a Contact Lens Dry Eye Questionnaire (CLDEQ-8) for comfort analysis.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 38 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •The Ocular Surface Disease Index questionnaire (OSDI) score for dry eye classification is ≤ 13
- •Participants must be candidates for contact lens wear.
- •Corneal radius between 7.4mm and 8.0mm
- •If the corneal radius is > 8.0mm, the corneal diameter must be greater than 12.0mm.
- •If the corneal radius is <7.4mm, the required corneal diameter is less than 12.0mm.
- •Participants have a CL cylindrical ametropia ≤ -1.25 D.
- •Participants will not have worn CL for 7 days prior to the start of the study.
- •Participants do not wear CL regularly (no more than 1 days per week) prior to the start of the study.
- •During the study, the participant wore the CL a minimum of 5 days per week for a minimum of 8 hours.
- •The person being tested is in good health. This means that he or she does not suffer from any systemic diseases, such as diabetes or rheumatism, which could have an influence on eye health. He or she also has no eye disease and has not previously undergone corneal (refractive) surgery.
排除标准
- •The participant is a minor.
- •The participant has worn CL within the last 7 days.
- •The radius of the cornea is not within the prescribed range. In addition, the corneal diameter is not within the prescribed range either.
- •The participant's ametropia is not within the prescribed range.
- •The participant has worn the lenses for less than 8 hours for less than five days.
- •The participant has no diagnosis of dry eye.
- •The OSDI questionnaire score for the Dry Eye classification is greater than
- •The participant suffers from a systemic disease (diabetes or rheumatism) that could influence ocular health, an ocular disease or has already undergone refractive surgery.
- •Vulnerable participants
研究组 & 干预措施
Daily contact lens wear
Participant wear silicone hydrogel contact lenses daily for 6 weeks ±2 days for a minimum wearing time of 5 days per week and 8 hours per day - corneal sensitivity will be measured and compared at baseline versus after 7±2 days and 5 weeks ±2 days daily contact lens wear.
干预措施: Device: silicone hydrogel contact lens (Other)
结局指标
主要结局
Difference in corneal sensitivity threshold baseline and after one and six weeks of daily contact lens wear
时间窗: 7±2 days and 5 weeks ±2
Comparison of corneal sensitivity threshold at the baseline and after one and six weeks of daily wear of silicone hydrogel contact lenses on neophyte wearer. Corneal sensitivity measurement will take place with the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) and will be recorded in mbar.
次要结局
- Correlation between corneal sensitivity threshold and subjective symptoms(7±2 days and 5 weeks ±2)
研究者
Daniela Nosch
Clinical Professor
University of Applied Sciences and Arts Northwestern Switzerland