A Prospective Study to Bilaterally Compare a New FDA-Approved Non-Invasive Cardiac Output Monitor in Children Undergoing General Anesthesia
试验速览
- 阶段
- 不适用
- 入组人数
- 50
- 试验地点
- 1
- 主要终点
- Bilateral cardiac output using the Cardiotronic ICON non-invasive cardiac output monitor.
研究概览
简要总结
Study hypothesis: The Cardiotronic ICON non-invasive cardiac output monitor gives accurate information when placed on a patient's Right or Left side.
Summary: To simultaneously compare physiologic data collected from two non-invasive cardiac output monitors placed bilaterally on pediatric patients undergoing general anesthesia. The FDA approved Cardiotronic ICON non-invasive cardiac output monitor has been validated by the manufacturer in pediatric and adult patients with leads placed on the left side. However, sometimes the surgical site and/or patient position precludes placement of the monitor leads on the left side. In such situations it would be useful to know whether placement of the monitor's leads on a patient's right side gives accurate cardiac output data. We will prospectively collect, and compare, simultaneous physiologic data for all enrolled children using two monitors, one on the patient's right side and one on the patient's left side.
详细描述
Traditionally cardiac output has been estimated with thermodilution, Fick oxygen consumption or with echocardiography. Other non-invasive techniques such as analysis of arterial wave forms and measurement of expired carbon dioxide have been attempted but with variable success. Recently a new device (Cardiotronic® EC™) has been approved by the FDA for use in children of all ages including neonates. Electrical cardiometry is a new method which can continuously estimate stroke volume and left ventricular outflow to calculate cardiac output, calculate cardiac index, as well as a variety of other parameters through quantitation of changes in impedance associated with changes in the orientation of red blood cells. During diastole red cells are organized chaotically but during systole they assume a position parallel to the direction of blood flow. Thus thoracic electrical bioimpedance relate to changes in thoracic aortic blood flow and through the use of refined algorithms non-invasive measurement of cardiac output is achieved.
The height (cm), gender, weight (kg) and age of the patient are entered into the hand-held device. Eight electrodes are applied to the neck and chest at specified locations, four per device. The device records the heart rate and averages cardiac output every 10-60 heartbeats again depending upon how the device is configured.
This is a prospective, non-randomized study to collect data from two noninvasive FDA-approved cardiac output monitors simultaneously in pediatric patients under general anesthesia in the operating room from age 1 month old to 8 years old with all types of medical conditions. We will enroll 50 male and female pediatric patients who are having lower abdominal and lower extremity surgery in this study so that the additional 8 EKG leads placed on the patients do not interfere with the surgical site or patient positioning.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 1 Month 至 8 Years(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •1 month old to 8 years old.
- •Lower abdominal or lower extremity surgery.
排除标准
- •Less than 1 month old.
- •Greater than 8 years old.
- •Patients undergoing upper abdominal, thoracic, upper extremity, or head/neck surgery.
结局指标
主要结局
Bilateral cardiac output using the Cardiotronic ICON non-invasive cardiac output monitor.
时间窗: 6 months
To simultaneously compare physiologic data collected from two non-invasive cardiac output monitors placed bilaterally on pediatric patients undergoing general anesthesia. The FDA approved Cardiotronic ICON non-invasive cardiac output monitor has been validated by the manufacturer in pediatric and adult patients with leads placed on the left side. However, sometimes the surgical site and/or patient position precludes placement of the monitor leads on the left side. In such situations it would be useful to know whether placement of the monitor's leads on a patient's right side gives accurate cardiac output data. We will prospectively collect, and compare, simultaneous physiologic data for all enrolled children using two monitors, one on the patient's right side and one on the patient's left side.
次要结局
未报告次要终点
研究者
Thomas Anthony Anderson
Assistant in Anesthesia
Massachusetts General Hospital