跳至主要内容
临床试验/NCT03463447
NCT03463447已完成不适用

Measurement of Handgrip Strength and Pinch of Children and Adolescents Using an Electronic Dynamometer

University of Mogi das Cruzes2 个研究点 分布在 1 个国家目标入组 360 人开始时间: 2017年5月8日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
360
试验地点
2
主要终点
Force

研究概览

简要总结

This study has quantified the hand strength in movements of handgrip and pinch with electronic dynamometer.

详细描述

The hand is considered the most improved tool and differentiated of the human, with great importance in the accomplishment of numerous actions due to an essential function: The handgrip strength. The handgrip and pinch movements are very important for an accomplishment of daily activities. For an evaluation of the movements, the dynamometry has been used in many fields of health and frequently in the area of rehabilitation. However, if the type of dynamometer used is not suitable for children, a measurement of the handgrip may be compromised. Therefore, the present study verified the effectiveness of an electronic dynamometer to evaluate the handgrip strength and pinch in children and adolescents.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
6 Years 至 17 Years(Child)
性别
All
接受健康志愿者

入选标准

  • neurological disorder Absence
  • Informed Consent signed by the responsible
  • with preserved cognitive.
  • consent form signed by the volunteer

排除标准

  • change Absence of skeletal muscle in the upper limbs

研究组 & 干预措施

Hand strength

Experimental

We selected volunteers without motor abnormalities with aged 6 to 17 years divided in groups (n = 30) according to an age group. The tests were performed in a single session lasting 20 minutes, when volunteers used a hydraulic dynamometer and an electronic dynamometer, in order to quantify the hand strength.

干预措施: Electronic Dynamometer (Device)

Hand strength

Experimental

We selected volunteers without motor abnormalities with aged 6 to 17 years divided in groups (n = 30) according to an age group. The tests were performed in a single session lasting 20 minutes, when volunteers used a hydraulic dynamometer and an electronic dynamometer, in order to quantify the hand strength.

干预措施: Hydraulic dynamometer (Device)

结局指标

主要结局

Force

时间窗: 15 minutes

The force of handgrip, pinch pulp-side and pinch pulp-pulp movement. The test was measured 3 times with 1 minute interval . Unit of measurement: kilogram - force (kgf).

次要结局

  • Anthropometric variables (Measurements of the hands)(3 minutes)
  • Anthropometric variables (weight)(1 minute)
  • Anthropometric variables (height)(1 minute)

研究者

发起方
University of Mogi das Cruzes
申办方类型
Other
责任方
Principal Investigator
主要研究者

Silvia Regina M. S. Boschi

PhD

University of Mogi das Cruzes

研究点 (2)

Loading locations...