MedPath

A Feasibility Study Implant of the WiSE® CRT System With an Intracardiac Pacemaker to Achieve Totally Leadless CRT

Not Applicable
Not yet recruiting
Conditions
Heart Failure
Interventions
Device: WiSE CRT System
Registration Number
NCT06561932
Lead Sponsor
EBR Systems, Inc.
Brief Summary

Assess the safety and efficacy of the co-implantation of the WiSE CRT System with an intracardiac pacemaker to provide totally leadless CRT.

Detailed Description

The WiSE CRT System is an implantable cardiac system to provide left ventricular (LV) pacing stimulation in conjunction with a co-implanted system that provides right ventricular (RV) stimulation. In combination, the devices deliver biventricular (BiV) pacing.

Single-arm, prospective, multicenter, observational study.

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
40
Inclusion Criteria
  • Patient with a class I or IIa (1) or (2) indication for implantation of a CRT device according to current available guidelines 1,2,4 (with additional QRS criteria on Class IIa (1)):

    • Class I: NYHA II, III, IV, EF ≤ 35%, LBBB, QRS ≥ 150 ms
    • Class IIa (1): NYHA II, III, IV, EF ≤ 35%, LBBB, QRS ≥ 130 to < 150 ms
    • Class IIa (2): NYHA II, III, IV, EF ≤ 35%, non-LBBB, QRS ≥ 150 ms
  • Patient or legally authorized representative can provide written authorization and/or consent per institution requirements

  • Male or Female, aged 22 years or above

  • Meets criteria for one of the two patient groups

    • Group A: De novo totally leadless CRT implant in whom the physician believes a totally leadless approach would be beneficial (e.g., wish to avoid lifelong transvenous lead implant, anatomical constraints, history of device infection).

      • Patients with symptomatic AF and an uncontrolled heart rate who are candidates for AV node ablation (irrespective of QRS duration and LVEF), and in whom the physician believes a leadless pacing approach would be beneficial.
      • Patients with high degree AV block who have an indication for permanent pacing (with a LVEF ≤ 50%), are expected to require ventricular pacing more than 40% of the time, and in whom the physician believes a leadless approach would be beneficial.
    • Group B: Upgrade chronic intracardiac pacemaker to CRT

      • Patients with existing intracardiac pacemakers with greater than 20% RV pacing, who have developed symptomatic HF.
Exclusion Criteria
  • Patient who is or is expected to be inaccessible for follow-up visits
  • Female participant who is pregnant, lactating, or planning pregnancy during the course of the study
  • Inability to comply with the study follow-up or other study requirements
  • History of chronic alcohol/ drug abuse and currently using alcohol/ drugs
  • Non-ambulatory (or unstable) NYHA class 4
  • Life expectancy less than 12 months
  • Any other significant disease or disorder which, in the opinion of the Investigator, may either put the participants at risk because of participation in the study, or may influence the result of the study, or the participant's ability to participate in the study.
  • Patient who is enrolled in another clinical study that could confound the results of this study (Note: patients enrolled in complementary study are eligible for enrolment)

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Single-arm, prospective, multicenter, observational study.WiSE CRT System.WiSE System therapy ON with Guideline Directed Medical Therapy
Primary Outcome Measures
NameTimeMethod
Bi-Ventricular capture on 12 lead EKG1 month and 6 months

Performance

Incidence of Device and procedure related complications.1 month and 6 months

Primary Safety

Secondary Outcome Measures
NameTimeMethod
Change in ejection fraction (EF) from Baseline6 months

Secondary efficacy 1

Change in Six-minute walk test6 months

Secondary efficacy 4

Change in NYHA class6 months

Secondary efficacy 3

Change in in left ventricular end systolic volume (LVESV)6 months

Secondary efficacy 2

Trial Locations

Locations (5)

Patients of Sunshine Coast University Hospital

🇦🇺

Birtinya, Queensland, Australia

Patients of Cairns Base Hospital

🇦🇺

Cairns, Queensland, Australia

Royal Brisbane and Women's Hospital

🇦🇺

Herston, Queensland, Australia

Patients of Gold Coast University Hospital

🇦🇺

Southport, Queensland, Australia

Princess Alexandra Hospital

🇦🇺

Woolloongabba, Queensland, Australia

© Copyright 2025. All Rights Reserved by MedPath