跳至主要内容
临床试验/NCT05880836
NCT05880836已完成不适用

In Line Aerosol Nebulization With High Flow

University of California, Los Angeles4 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2023年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
40
试验地点
4
主要终点
Maximal decrease in SpO2 during nebulization with jet nebulizer vs. inline via HFNC compared to the baseline SpO2 values prior to the nebulization therapy

研究概览

简要总结

The objective of ILAN is to assess the safety, feasibility and bronchodilator efficacy of in-line bronchodilator nebulizer delivery with VMN via HFNC system in hypoxemic respiratory failure patients treated with bronchodilators and compare this method to standard-nebulization using a jet nebulizer with a facial mask. The investigators hypothesized that aerosol nebulization using HFNC/VMN represents safer and more convenient approach in hypoxemic respiratory failure patients in comparison to conventional therapy while providing similar bronchodilator efficacy.

详细描述

Objective: To evaluate the safety and feasibility of a novel approach to nebulization treatment via the nasal route in patients with severe hypoxemic respiratory failure dependent on high flow oxygen.

Hypothesis: In-line vibrating mesh nebulizer delivery via HFNC systems is a safe, feasible and efficacious approach in comparison to traditional jet nebulizer delivered nebulization in hypoxemic respiratory failure patients whose usual care includes nebulized drugs.

Specific Aims:

  1. To evaluate the safety and feasibility of administering vibrating mesh nebulizer-delivered therapy in patients with acute hypoxemic respiratory failure requiring high flow nasal cannula.
  2. To evaluate the effect of trans-nasal nebulization on patient comfort and satisfaction with therapy in comparison with standard jet nebulization.
  3. To evaluate differences in resource utilization between patients receiving standard jet nebulization and ILAN with HF, including time spent at the bedside by the respiratory therapist (RT) for delivery of the medication and any additional time gathering setting up and cleaning.
  4. To evaluate patient and therapist perceptions and preference on the various delivery methods of aerosol delivery.

Study Design: ILAN is a double-crossover, multi-center trial evaluating the safety and feasibility of in line nebulized medication with high flow nasal canula in comparison to standard jet nebulizer therapy in acute respiratory failure requiring the utilization of high flow nasal cannula.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Supportive Care
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults ≥ 18 years of age
  • Patients with mild or moderate hypoxemic respiratory failure (with or without acute hypercapnic respiratory failure) treated with HFNC.
  • Nebulizer therapy ordered by the primary team with at least one dose delivered prior to the enrollment into the study
  • Patients must be on ordered nebulized albuterol, levalbuterol, ipratropium or ipratropium/albuterol combination with a maximum of Q3 or a minimum of Q6 hour frequencies.
  • For Respiratory Therapists: They must be employees of SMICU or RRMC.

排除标准

  • Lack of hypoxemia defined as SpO2> 92% on room air
  • Severe hypoxemia defined by PaO2/FiO2<100 or SpO2<92% on HFNC settings: ≥ FiO2 80% or higher and O2 flow 40L/min
  • HFNC O2 delivery via tracheostomy
  • COVID-19 positive status (within 3 weeks prior to the enrollment)
  • Respiratory distress, defined by respiratory rate > 24 breath per minute
  • Hemodynamic instability defined by the use of two or more vasopressor medications
  • Presence of nasal obstruction that may pose a risk for inadequate nebulizer delivery in the opinion of the investigator
  • Pulmonary comorbidities that, in the opinion of the investigator or clinical team, can pose a risk to subject safety or interfere with the subject's ability to complete the study procedures.
  • Moribund patient not expected to survive >24 hours
  • Inability to obtain informed consent from patient
  • Respiratory therapists who are unwilling to participate.

结局指标

主要结局

Maximal decrease in SpO2 during nebulization with jet nebulizer vs. inline via HFNC compared to the baseline SpO2 values prior to the nebulization therapy

时间窗: up to 48 hours

Primary Outcome

次要结局

  • Proportion of patients with documented hypoxemia (<88%) during the nebulization(up to 48 hours)
  • ROX score(up to 48 hours)
  • Requirement for additional interventions to maintain patient's safety during the nebulization(up to 48 hours)
  • Duration of hypoxemic episodes with SpO2<88% during the nebulization delivery(up to 48 hours)
  • Change in respiratory rate during nebulization compared to the baseline rate(up to 48 hours)
  • Nosebleed within 2 hours of nebulizer delivery(up to 48 hours)
  • Lowest absolute desaturation from the beginning until completion of nebulizer treatment compared to the baseline SpO2 values defined as the lowest adequately measured SpO2 within two minutes prior to the nebulization(up to 48 hours)
  • Increase in respiratory rate from the baseline during the nebulization by >10%(up to 48 hours)
  • Need to increase O2 support after the nebulization therapy to maintain SpO2>88%(up to 48 hours)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Igor Barjaktarevic, MD, PhD

Associate Professor

University of California, Los Angeles

研究点 (4)

Loading locations...

相似试验