Retinal Nerve Fiber Layer Thickness Changes in Migraine: A Meta-Analysis of Case-control Studies
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 500
- 试验地点
- 1
- 主要终点
- Retinal Nerve Fiber Layer Thickness
研究概览
简要总结
Optical coherence tomography (OCT) is a non-invasive retinal imaging technology that can provide high-resolution cross-sectional images of the peripapillary retinal nerve fiber layer (RNFL) and measure its thickness. A reduction of the RNFL thickness has been detected in several neurodegenerative diseases, such as multiple sclerosis, CADASIL and Alzheimer's disease. Different studies have reported RNFL changes also in migraine, is a common hereditary chronic neurovascular disorder, characterized by dysfunction of the autonomic nervous system. The pathophysiology of migraine has not been fully clarified, but there is increasing evidence that episodes of migraine with aura are initiated by a focal reduction in cerebral blood flow, which occurs most commonly in the posterior region of one hemisphere. Although vasoconstriction of cerebral and retinal blood vessels is a transient phenomenon, the chronic nature of the migraine might cause permanent structural abnormalities of the brain and also of the retina, which may correlate with RNFL thinning. Previous studies on this subject, however, reported contradicting results. Some investigations reported reductions of the RNFL thickness while others did not. In the present study, in order to determine whether RNFL thickness is reduced in migraine patients, the investigators performed a meta-analysis and systematically evaluated RNFL thickness measurements with OCT in a series of migraine patients and in the healthy control groups.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Control
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •case-control studies;
- •patients with Migraine were compared with healthy controls;
- •all subjects underwent RNFL thickness measurement by OCT;
- •studies should provide the data of peripapillary RNFL thickness;
- •sample size ≥10 in each group.
排除标准
- •authors did not make RNFL measurements;
- •study without healthy control group;
- •the outcome values can not be used for meta-analysis;
- •duplicated articles.
结局指标
主要结局
Retinal Nerve Fiber Layer Thickness
时间窗: Baseline
Retinal nerve fiber layer thickness included average thickness (360° measurement), temporal quadrant thickness (316-45°), superior quadrant thickness (46-135°), nasal quadrant thickness (136-225°) and inferior quadrant thickness (226-315°)was measured by OCT.
次要结局
未报告次要终点
研究者
Yifan Feng
Zhongshan hospital, Fudan University
Wenzhou Medical University
