Clinical Evaluation of a Laser Heated, Fiberoptic-Coupled Radiation Dose Verification System

National Cancer Institute (NCI)2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 1997年7月最近更新:
适应症

试验速览

阶段
1 期
状态
已完成
入组人数
20
试验地点
2

研究概览

简要总结

We propose to determine the response of a newly developed laser heated, vycor glass fiberoptic radiation dosimetry system to ionizing radiation in a clinical radiotherapy environment. Present systems measure only total dose or have limitations, such as instability, non-linearity, excessive size or a decoupled measurement system, making them unsuitable in a variety of clinical applications. This fiberoptic coupled dosimetry system is a new and innovative technology application which allows on-line measurement of instantaneous dose rate and total dose never before achievable. It offers a clear advantage in patient treatment delivery, allowing on-line corrections essential to a new generation of radiotherapy treatment machines with development of beam intensity modulation as an adjunct to 3D conformal therapy. It also has the advantage of submillimeter size and is minimally invasive, making it ideal for brachytherapy.

This system has the potential for stable, accurate, reproducible, clinically feasible measurements of total dose and dose rate. The output of this system will be measured under various clinical conditions encountered in a clinical setting and compared against existing thermolumeniscent and diode dosimetry standards. Initial measurements will use a tissue equivalent phantom for depth dose and accuracy measurements. Additional studies will include dosimetric measurements of routine clinical treatment setups on patients receiving therapeutic irradiation.

详细描述

We propose to determine the response of a newly developed laser heated, vycor glass fiberoptic radiation dosimetry system to ionizing radiation in a clinical radiotherapy environment. Present systems measure only total dose or have limitations, such as instability, non-linearity, excessive size or a decoupled measurement system, making them unsuitable in a variety of clinical applications. This fiberoptic coupled dosimetry system is a new and innovative technology application which allows on-line measurement of instantaneous dose rate and total dose never before achievable. It offers a clear advantage in patient treatment delivery, allowing on-line corrections essential to a new generation of radiotherapy treatment machines with development of beam intensity modulation as an adjunct to 3D conformal therapy. It also has the advantage of submillimeter size and is minimally invasive, making it ideal for brachytherapy.

This system has the potential for stable, accurate, reproducible, clinically feasible measurements of total dose and dose rate. The output of this system will be measured under various clinical conditions encountered in a clinical setting and compared against existing thermolumeniscent and diode dosimetry standards. Initial measurements will use a tissue equivalent phantom for depth dose and accuracy measurements. Additional studies will include dosimetric measurements of routine clinical treatment setups on patients receiving therapeutic irradiation.