Comparative Study of DaTSCAN ™ Cerebral SPECT Recorded by Conventional Anger Cameras and Semiconductor Camera (VERITON-CT ™)

Central Hospital, Nancy, France2 个研究点 分布在 1 个国家目标入组 96 人开始时间: 2019年9月5日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
96
试验地点
2
主要终点
Degree of concordance (Kappa) of the exams results of different records

研究概览

简要总结

The semiconductor (cadmium-zinc-telluride, CZT) cameras significantly increase detection sensitivity in Single Photon Emission Computer Tomoscintigraphy (SPECT)(1) . The clinical routine applications of these cameras are today mainly limited to myocardial tomoscintigraphy with CZT dedicated cameras. Several studies whose one was done in Hospital of Nancy, made it possible to demonstrate a good diagnosis agreement between conventional cameras and semiconductor cameras in this indication, with better image quality obtained with semiconductor cameras (2). Today, so-called "wide field" semiconductor cameras are available in the clinic and allow for any type of SPECT examination. A comparative study between conventional and semiconductor cameras has been conducted for bone scintigraphy, and shows diagnostic superiority with this new type of camera (3).

In addition, the new VERITON-CT ™ (Spectrum Dynamics Medical) camera has 12 mobile CZT-based detectors positioned around the patient allowing tomographic acquisitions and focusing the acquisition on the organ studied. This camera has a sensitivity of detection higher than that of conventional cameras and thus reduces the activity injected into the patient and / or the recording time.

To date, no study has compared the two types of cameras in nuclear neurology and in particular, for the SPECT DaTSCAN ™ imaging of the pre-synaptic dopaminergic pathway.

DaTSCAN ™ exam is used in clinical routine:

  1. for the diagnosis of Parkinson's disease or related diseases when in doubt with an essential tremor (4) or
  2. if suspicion of Lewy body disease, if in doubt with Alzheimer's disease (5). If the interpretation of DaTSCAN ™ exam is first visual, the quantification may increase accuracy diagnosis (6). Also, the database creation specific to each type of camera is recommended(7).

The purpose of this study is to compare the diagnostically relevant informations and the quantitative analysis provided by the DaTSCAN™ SPECT, recorded on the conventional camera and recorded on the semiconductor camera VERITON-CT™

详细描述

The clinical study is monocentric, interventional, non randomized, with minimal risk and constraints.

All patients going to the nuclear medicine department for a DaTSCAN exam will be able to participate in this study if they understood study informations given by the physician and if they signed the inform consent.

In first, patients will have a DaTSCAN™ SPECT on a conventional camera and after, they will have DaTSCAN™ SPECT on VERITON-CT™ camera with two records: one in focus striatum mode and the second in focus brain mode.

The attenuation correction will be made with the computer tomography (CT) recorded at the same time as the SPECT (SPECT/CT)

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • all patients over 18 years sent to Datscan SPECT/CT
  • patients understanding and having signed the informed consent form.
  • without contraindication to have the scintigraphy
  • patient subject to a medical benefits scheme

排除标准

  • known allergy to the one of the components of Datscan
  • pregnant, parturient or breastfeeding woman
  • major person under legal protection (any form of public guardianship)
  • major person unable to express consent
  • person deprived of liberty due to judicial or administrative decision.

结局指标

主要结局

Degree of concordance (Kappa) of the exams results of different records

时间窗: 16 months

comparison between the exam results (positive diagnosis of Parkinson disease or Lewy bodies dementia versus differential diagnosis) in conventional camera and the one obtained with the VERITON-CT in striatum focus mode

次要结局

  • Degree of concordance (Kappa) of the exams results of different recordings(16 months)

研究者

发起方
Central Hospital, Nancy, France
申办方类型
Other
责任方
Principal Investigator
主要研究者

Antoine VERGER

MD, PhD

Central Hospital, Nancy, France