Cerebral and Circulatory Effects of Neonatal Volume Targeted Ventilation
- Conditions
- Respiratory FailureRespiratory Distress Syndrome, NewbornPremature Birth
- Interventions
- Other: volume guaranteeOther: pressure-controlled
- Registration Number
- NCT04391634
- Lead Sponsor
- Poznan University of Medical Sciences
- Brief Summary
The aim of the study was to assess the effect of volume targeted vs. pressure-controlled mechanical ventilation (MV) on circulatory parameters and cerebral oxygenation in the extremely preterm infants.
- Detailed Description
Prospective, cross-over trial enrolling neonates \<28 weeks' gestation requiring MV. Patients were ventilated for 3 hours with pressure controlled assist-control (PC-AC) mode, followed by 3-hours of volume guarantee assist-control ventilation (VG-AC). Continuous monitoring was carried out using pulse oximetry (oxygen saturation - SpO2 and heart rate - HR), near-infrared spectroscopy (cerebral oxygenation - StO2) and electrical cardiometry (circulatory parameters).
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 25
- premature infants born <28 weeks of gestation
- respiratory failure in the course of respiratory distress syndrome requiring mechanical ventilation
- stable condition with pH (acidity of blood)> 7.2 and pCO2 (carbon dioxide partial pressure) <60 mmHg in the blood gas analysis
- no identified genetic syndromes and serious congenital malformations
- lack of written consent of patients' parents
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Mechanical ventilation pressure-controlled Preterm infants on mechanical ventilation Mechanical ventilation volume guarantee Preterm infants on mechanical ventilation
- Primary Outcome Measures
Name Time Method Stroke volume variation (SVV) 6 hours Stroke volume variation (SVV) monitored with electrical cardiometry \[percent\]
Index of contractility 6 hours Index of contractility (ICON) monitored with electrical cardiometry
Stroke volume 6 hours Stroke volume (SV) monitored with electrical cardiometry \[ml\]
Cardiac output 6 hours Cardiac output (CO) monitored with electrical cardiometry \[L/min\]
Stroke index 6 hours Stroke index (SI) monitored with electrical cardiometry \[ml/m2\]
Cardiac index 6 hours Cardiac index (CI) monitored with electrical cardiometry \[L/min/m2\]
StO2 6 hours Cerebral oxygenation measured using near-infrared spectroscopy \[percent\]