Can Dynamic Ultrasonography Replace Urodynamics in Follow-up of Patients With Myelomeningocele
- Conditions
- Neurogenic BladderMyelomeningocele
- Interventions
- Diagnostic Test: Dynamic Ultrasonography
- Registration Number
- NCT03550898
- Lead Sponsor
- Hospital de Clinicas de Porto Alegre
- Brief Summary
Patients with neurogenic bladder need periodic evaluation with urodynamic study, a invasive and uncomfortable procedure.
Aim: To evaluate the accuracy of dynamic ultrasonography as a feasible and noninvasive alternative diagnostic method to identify detrusor overactivity in patients with neurogenic bladder
- Detailed Description
The urodynamic study and dynamic ultrasonography were performed concurrently, to identify detrusor overactivity, in patients with myelomeningocele and clinical indication for urodynamics, by investigators without verbal or visual contact.
The overactivity was diagnosed through active conformational change of the bladder during filling phase.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 81
- All outpatients of the Pediatric Urology Department of the investigator's institution with diagnosis of myelomeningocele and clinical indication for urodynamic study
- Previous bladder augmentation surgery
- Current urinary tract infection
- Fail to provide consent for participation
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Dynamic ultrasonography Dynamic Ultrasonography Dynamic ultrasonography was performed in all patients who underwent urodynamics, simultaneously.
- Primary Outcome Measures
Name Time Method To evaluate the accuracy of dynamic ultrasonography to identify bladder overactivity in neurogenic bladder. 20 minutes Dynamic Ultrasonography evaluated the dynamic conformational change of the bladder to identify the presence of detrusor overactivity, based on a subjective graduation of contractions, compared to the urodynamic data.
- Secondary Outcome Measures
Name Time Method To evaluate the accuracy of dynamic ultrasonography to identify maximum cystometric capacity. 20 minutes The bladder maximum capacity was measured at the end of the filling phase, based on the ellipse formula and compared to the infused volume in urodynamics.
To assess the ability of dynamic ultrasonography to estimate the pressure of detrusor contractions. 20 minutes According to the detrusor mobility and bladder deformity, the contractions were graded: 1 - no contractions; 2 - partial contraction of bladder floor; 3 - partial contraction of bladder floor and posterior wall; 4 - generalized contraction with modification of bladder shape from ellipsoid to round. These data were compared to the maximum pressure data recorded in the urodynamic study.