MedPath

A Clinical Trial to Verify the Efficacy and Safety of Electric Phlegm Suction System

Not Applicable
Conditions
Other Specified Respiratory Disorders
Interventions
Device: unmanned electric phlegm suction system procedure using an investigational device (LMECA.A1000)
Procedure: Manual phlegm suction system
Registration Number
NCT05236400
Lead Sponsor
Lmeca
Brief Summary

Manual airway aspiration is a task performed by a nurse or caregiver and if the nursing/care work is overloaded, it has the disadvantage that airway aspiration cannot be performed an appropriate number of times according to the needs of the patient. Therefore, an electric phlegm suction system that can compensate for the shortcomings has been developed. The purpose of this clinical trial is to compare and evaluate the efficacy and safety of the test device by applying the unmanned electric phlegm suction system procedure using an investigational device (LMECA.A1000) and the conventional manual airway aspiration procedure to the patients who received mechanical ventilation through the artificial airway in this clinical trial.

Detailed Description

Not available

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
148
Inclusion Criteria
  • Those aged ≥19 among the in-patients in the intensive care unit of the study site.
  • Patients who have been applied with mechanical ventilation through the artificial airway such as tracheal intubation or tracheotomy and have maintained PaO2/FiO2 values above 100mmHg.
  • Patients whose application time of mechanical ventilation does not exceed 36 hours
  • Those who are expected to see continued application of mechanical ventilation for at least 72 hours after participating in this study
Exclusion Criteria
  • The subject or a legally acceptable representative refuses to participate in the study
  • Those who have become pregnant or are planning to become pregnant during the study period
  • Patients who need to maintain their plateau pressure with the mechanical ventilation setting of FiO2 exceeding 80% or exceeding Pplat of 30cmH2O.
  • Patients with severely lowered immune function such as advanced hematologic malignancy, bone marrow transplantation failure, agranulocytosis, and absolute neutrophil count (ANC) of <500/mm3
  • Those with unstable cardiovascular conditions such as arrhythmia accompanied by hemodynamic instability and severe hypoxemia
  • Those who continue to bleed due to hemorrhagic causes, including multiple traumas or thrombocytopenia
  • If the patient is scheduled for or had performed a solid organ transportation on the day of study participation, or self-recovered through cardiopulmonary resuscitation (CPR)
  • Patients with pulmonary disease accompanied by hemoptysis
  • In addition, if the medical staff decides that it is not appropriate to apply the investigational device to the subject or perform bronchoscopy

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
unmanned electric phlegm suction system procedure using an investigational device (LMECA.A1000)unmanned electric phlegm suction system procedure using an investigational device (LMECA.A1000)After participating in a clinical trial and receiving unmanned electric airway aspiration, the efficacy and safety are checked on Day 3 and on Day 7 and Day 14 of the follow-up period.
Manual phlegm suction systemManual phlegm suction systemAfter participating in a clinical trial and applying manual airway aspiration, the efficacy and safety are checked on Day 3 and on Day 7 and Day 14 of the follow-up period.
Primary Outcome Measures
NameTimeMethod
Evaluation of airway mucosal damage change on 72 hours after application through bronchoscopy results72 hours after application of the investigational device

Comparative assessment on the damage of the airway mucosa between the test group and the control group through bronchoscopy results

Secondary Outcome Measures
NameTimeMethod
Evaluation of airway mucosal damageAt each time point before the application, 7 days, and 14 days after the application of the investigational device

Comparison of the difference in the degree of damage to the airway mucosa between the test group and the control group

Incidence of mechanical ventilation-related pneumoniaFor 2 weeks from the time of investigational device application

Difference in the incidence of ventilator-associated pneumonia between the test group and the control group group

Rate of investigational device malfunctionFor 2 weeks from the time of application of investigational device

The incidence of malfunction of the investigational device that has been applied to the test group

Trial Locations

Locations (3)

Korea University Guro Hospital

🇰🇷

Seoul, Korea, Republic of

Korea University Anam Hospital

🇰🇷

Seoul, Korea, Republic of

Korea University Ansan Hospital

🇰🇷

Seoul, Korea, Republic of