Assessment of Sustained Systolic-to-diastolic Flexibility of the Mitral Valve Annulus With the Sorin MEMO 3D Mitral Anuloplasty Ring

University Hospital, Ghent2 个研究点 分布在 1 个国家目标入组 33 人开始时间: 2014年1月16日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
33
试验地点
2
主要终点
Difference of diameters and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device.

研究概览

简要总结

Mitral valve reconstruction commonly requires the use of an anuloplasty device to assure long-term durability of the repair. Among mitral anuloplasty devices, varying from rigid to complete flexible ring substitutes, the most recent ones are aimed to restore the natural saddle shape of the mitral annulus, in order to decrease the stress tension on both mitral leaflets and chordal attachments. So far, even for flexible ring devices, the sustained flexibility of the device remained unproven, probably by cicatricial fibrotic tissue ingrowth after implantation.

Due to specific structural characteristics based on a nitinolstent with carbofilm-coating, the MEMO 3D ring device of SORIN claims preservation of the ring flexibility during the cardiac cyclus. Consequently, mitral anuloplasty with this device is expected to decrease the stress during the systolo-diastolic movements of the valve, and so, improve the late durability of the repair.

Echocardiography is the first-line technique for mitral valve assessment after surgical repair, for both intra-operative evaluation and serial follow-up of valve function. Recently, three-dimensional echocardiography has been introduced into clinical practice, affording qualitative and quantitative measurement of mitral valve function and size during the cardiac cycle.This method allows to quantify precisely the excursion of the mitral annulus between systole and diastole.

The aim of this study is to analyse the systolo-diastolic movement of the mitral annulus after the use of an anuloplasty with the SORIN MEMO 3D device, after surgical implantation and its sustainability, 1 year after implantation.

This hypothesis is tested in a case-controlled comparison with a standard used rigid ring device.

Therefore, 3-D echocardiography will be performed at the time of surgical repair, and after 1 year, to define the size and surface change of the mitral anuloplasty device during the cardiac cycle.

Based on a sample size calculation, 10 patients in each comparison group will be included, suggesting a study cohort of 20 patients eligible for mitral valve repair.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • All patients requiring the use of an mitral anuloplasty device to restore the mitral competence by surgery are potential candidates for study inclusion, if survival of at least more than 1 year is expected

排除标准

  • 未提供

结局指标

主要结局

Difference of diameters and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device.

时间窗: 1 year after implantation.

Difference of antero-posterior diameter, latero-lateral diameter and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device. The measurements are done with the use of 3-D echocardiography