MedPath

ECG Leadwires: Disposable Versus Cleaned, Reusable

Not Applicable
Completed
Conditions
Critically Ill Patients
Cardiovascular Surgery Telemetry Patients
Interventions
Other: Disposable ECG-LW
Registration Number
NCT01411553
Lead Sponsor
The Cleveland Clinic
Brief Summary

Null hypothesis: (1) there is no difference in rates of ICU-acquired infection based on using disposable or cleaned, reusable ECG leadwires and (2) In cardiac surgical telemetry floors, there is no difference in false or nuisance sightings or crisis calls based on using disposable or cleaned, reusable ECG leadwires.

Detailed Description

Primary purposes: Using a randomized controlled trial methodology and randomizing similar (matched) intensive care units (ICU) to either disposable or cleaned, reusable ECG-LW: 1. Is there a difference in the rate of blood stream infection (BSI) and ventilator-associated pneumonia (VAP) in ICU environments (medical ICU, surgical ICU, cardiothoracic ICU, and neuroscience ICU) and surgical site infection (SSI); specifically, sternal wound infections in cardiothoracic ICU that utilize disposable vs. cleaned, reusable ECG-LW? 2. Is there a difference in ICU length of stay based on ECG-LW used: disposable vs. cleaned, reusable? 3. After controlling for patient age, comorbidity index and after removing patients who's date of BSI or VAP infections were within 48 hours of admission to the ICU, is there a difference in the rate of (A) blood stream infection (BSI), (B) ventilator-associated pneumonia (VAP) and (C) SSI in ICU environments (when applicable) that utilize disposable vs. cleaned, reusable ECG-LW? Secondary purposes: Using a randomized controlled trial methodology and randomizing similar telemetry units to either disposable or cleaned, reusable ECG-LW: 1. Is there a difference in the number of false/nuisance sightings/crisis calls (i.e., lead off, no telemetry, lead failure or other false alarms) identified by the Central Monitoring Unit (CMU)? 2. Is there a difference in true sightings/crisis calls identified by the CMU based on unit assignment of disposable or cleaned, reusable ECG-LW? 2b. If yes to #2, is there a difference in types of true sightings/calls identified by the CMUbased on assignment of disposable or cleaned, reusable ECG-LW?

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
4056
Inclusion Criteria
  • Primary HO: patients treated in an ICU setting; Secondary HO: Patients treated in cardiac telemetry setting
Exclusion Criteria
  • None

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Disposable ECG leadwires-ICUDisposable ECG-LWDisposable ECG-LW
Primary Outcome Measures
NameTimeMethod
Blood stream infection7 months

culture findings

Secondary Outcome Measures
NameTimeMethod
false/nuisance alarms4 months

alarms generated by ECG tracings due to various causes (leads off, leads crimped, etc)

Trial Locations

Locations (1)

Cleveland Clinic

🇺🇸

Cleveland, Ohio, United States

© Copyright 2025. All Rights Reserved by MedPath