Different Stylet Angles for Orotracheal Intubation Using Glidescope® Video Laryngoscope in Children
- Conditions
- Intubation
- Interventions
- Device: Glidescope® with standard-curved tipDevice: Glidescope® with tip manipulated stylet
- Registration Number
- NCT02952690
- Lead Sponsor
- Seoul National University Hospital
- Brief Summary
The purpose of this study is to evaluate the feasibility of endotracheal intubation via glidescope videolaryngoscope (GVL) using different curve of stylet in 120 children aged between 1 and 5 year old.
- Detailed Description
Pediatric patients aged 1-5 year old are randomly assigned to one of two groups; standard curve (S) and tip-manipulated curve (T) groups. After routine anesthetic induction, endotracheal intubation is performed with GVL. Size of GVL blade is selected according to weight; GVL 0: \<1.5kg, GVL 1:1.5-3.6kg, GVL 2: 1.8-10kg, GVL 2.5: 10-28kg). Before intubation, stylet curve is differently manipulated according to group. The style is curved in accordance with the curve of GVL blade in S group, whereas the distal tip of style is additionally bended to the left (15-20 degree) in T group.
Time from visualization of glottis with GVL to approaching of endotracheal tube to glottis, and time to completion of intubation are measured. In addition, the easiness of intubation is assessed using Visual Analogue Scale (0: extremely easy, 10: extremely difficult) and will be compared in both groups.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 120
- children aged between 1 and 5 years who are scheduled for elective surgery
- American Society of Anesthesiologist physical status I, II
- History of asthma
- Active upper respiratory infection
- Significant cardiopulmonary disease
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description standard curve group Glidescope® with standard-curved tip The style is curved in accordance with the curve of GVL blade in this group. tip-manipulated curve group Glidescope® with tip manipulated stylet The style is curved in accordance with the curve of GVL blade and the distal tip of style is additionally bended to the left (15-20 degree) in this group.
- Primary Outcome Measures
Name Time Method Time to tracheal intubation up to 3 min after insertion of GVL From the insertion of GVL to completion of endotracheal intubation
- Secondary Outcome Measures
Name Time Method Time to approaching of endotracheal tube tip to glottis up to 3 min after insertion of GVL From the insertion of GVL to approaching of endotracheal tube tip to glottis
Successful endotracheal intubation in 30 seconds up to 3 min after insertion of GVL Success or failure in completion of endotracheal intubation in 30 seconds
Number of attempt for glottis passage of endotracheal tube up to 3 min after insertion of GVL The change in stylet angle up to 3 min after insertion of GVL The number of additional manipulation of stylet for success of endotracheal intubation
Visual analogue scale for the easiness of endotracheal intubation up to 3 min after insertion of GVL Measurement of the easiness of endotracheal intubation
Trial Locations
- Locations (1)
SNUH
🇰🇷Seoul, Jongro Gu, Korea, Republic of