Vascular Positioning System G4 Algorithm ECG Data Collection for Model Training Study
- Conditions
- Peripheral ICC
- Interventions
- Other: Digital ECG Data Collection
- Registration Number
- NCT05702515
- Lead Sponsor
- Teleflex
- Brief Summary
The objective of this study is to collect intravascular and extravascular echocardiogram (ECG) data from subjects receiving peripherally inserted central catheters (PICC) while using the Vascular Positioning System G4 and a 12 lead ECG machine. The data obtained will be used to update the G4 algorithm.
- Detailed Description
This study seeks to collect synchronized digital data collected from the G4 and ECG machines during the PICC insertion procedure. A copy of the data will be downloaded from the G4 and ECG machines and submitted to the sponsor. Both the G4 and the ECG machine used for data collection in this study are FDA cleared/approved.
Study Design: This is a single center prospective clinical study. All enrolled subjects will receive a 12-lead ECG during PICC insertion and a chest x-ray post insertion. ECG lead will be documented via photographic imaging.
Duration of Subject Study Participation: Each subject's participation will start at the time of signing the informed consent and terminate upon completion of the x-ray.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- Male
- Target Recruitment
- 20
-
Male
- 21 years of age or older
- Scheduled for PICC insertion using the VPS G4 system
- Willing to allow thoracic photos to be obtained after ECG lead placement
-
Female
- ˂ 21 years of age
- Patient has a pacemaker
- Patient condition precluding ECG use and lead placement
- Patient condition precluding radiographic imaging
- Unwilling to allow thoracic photos to be obtained after ECG lead placement
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Adult male patients scheduled to receive a PICC insertion Digital ECG Data Collection Adult male patients scheduled to receive a PICC insertion using the Vascular Positioning System G4 tip navigation system
- Primary Outcome Measures
Name Time Method VPS G4 system digital data During PICC insertion procedure VPS G4 digital captured data recorded at 11.667 MHz measuring ISPTA.3 (mW/cm2) vs time (s).
Electrocardiograph digitally captured data During PICC insertion procedure Electrocardiograph digitally captured data recorded at a sample resolution of 4.88 μV/LSB @ 250 sps, 1.22 μV/LSB @ 500 sps and a frequency response of -3 dB @ 0.01 to 150 Hz vs time (s).
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Duke University Hospital
🇺🇸Durham, North Carolina, United States