Evaluation of the Argos System to Estimate Cardiac Output in Critically Ill Patients

Bicetre Hospital1 个研究点 分布在 1 个国家目标入组 120 人开始时间: 2026年2月1日最近更新:
适应症
相关药物

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
120
试验地点
1
主要终点
To compare the changes in cardiac output provided by the Argos system induced by changes in norepinephrine or fluid bolus, compared to cardiac output provided by the transpulmonary thermodilution device in critically ill patients.

研究概览

简要总结

The goal of this observational study is to evaluate the reliability of the Argos system to track changes in cardiac output in critically ill patients. The main question it aims to answer is:

Does cardiac output changes induced by fluid administration or changes in norepinephrine dosage can be tracked by the Argos system, compared to transpulmonary thermodilution device.

详细描述

In patients with acute circulatory failure, hemodynamic monitoring including cardiac index (CI) assessment is recommended for most severe patients. Transpulmonary thermodilution (TPTD) is one of the methods that are recommended for this purpose, in particular because it is considered as reliable in this type of patients. The PiCCO2 system (Pulsion Medical Systems, Getinge, Feldkirchen, Germany) relies on TPTD method and associate two methods to measure CI. On the one hand, TPTD is considered as one of the gold standards for CI evaluation (CITPTD). On the other hand, pulse contour analysis calculates stroke volume from the waveform of the systolic part of the arterial pressure curve (CIpwa). The way this estimation is performed and it is regularly re-evaluated differs among the devices that are available on the market. This estimation of CIpwa is calibrated when TPTD is performed. Thus, it allows a real-time pulse contour derived CI assessment, which is very precise. However, TPTD system are considered invasive, expensive and are not available in all settings.

The Argos monitor (Retia Medical, Valhalla, USA) uses the so-called multi-beat analysis (MBA) to estimate CI after analyzing the arterial pressure waveform over periods of multiple heartbeats (up to 20) and scaling CI estimations to biometric data. The algorithm estimates the theoretical central arterial blood pressure waveform using MBA, minimizing and avoiding the cofounding effect of the wave reflection phenomena. Based on this central arterial blood pressure waveform and biometric patient data, the system estimates cardiac output. The Argos monitor has a second advantage. It simply connects to the analogue output of the blood pressure signal from a compatible multi-parameter monitor and needs no additional specific pressure sensor. During cardiac surgery, the Argos monitor showed reasonable agreement and trending ability compared to the pulmonary artery catheter. However, in patients after cardiac surgery, including those with low cardiac output and arrhythmia, CI estimated by the device was not interchangeable with the continuous thermodilution method via a PAC.

The primary objective of the study is to evaluate the reliability of the Argos system to track changes of CI induced by changes in norepinephrine or fluid administration, compared to CITPTD in critically ill patients.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age ≥18 years old
  • Hospitalisation in intensive care
  • Haemodynamic monitoring with transpulmonary thermodilution already in place
  • Hemodynamic intervention deemed necessary by the clinician in charge of the patient
  • Administration of a fluid bolus
  • Change in norepinephrine dosage or performance of a vasopressor test

排除标准

  • Pregnancy
  • Other therapeutic modification during volume expansion or the vasopressor test
  • Refusal to participate by relatives of the patient or the patient himself or herself
  • Non availability of investigators

结局指标

主要结局

To compare the changes in cardiac output provided by the Argos system induced by changes in norepinephrine or fluid bolus, compared to cardiac output provided by the transpulmonary thermodilution device in critically ill patients.

时间窗: 1 hour (before and after intervention)

次要结局

  • Accuracy of the Argos system(1 hour (before and after intervention))
  • Precision of the Argos system(1 hour (before and after intervention))