MedPath

Three-dimensional Optical Surface Imaging as a Diagnostic Tool in Pectus Excavatum

Not Applicable
Conditions
Pectus Excavatum
Interventions
Other: 3D optical surface image
Radiation: CT scan
Radiation: Chest radiography
Registration Number
NCT03926078
Lead Sponsor
Zuyderland Medisch Centrum
Brief Summary

Pectus excavatum (PE) is the most common anterior chest wall deformity. Currently, a chest radiography (CR) or Computed Tomography (CT) scan is acquired to determine and objectify pectus severity using the Haller Index. Alongside other determinants, the Haller Index value is used in the proces of clinical decision making and determine surgical candidacy. However, cross-sectional imaging based calculation of the Haller Index implies exposure to ionizing radiation that should be limited at all times to diminish the cumulative long-term risks of malignancy. Especially in pectus patients that often concerns children.

Three-dimensional (3D) optical surface imaging offers a non-invasive, radiation-free alternative that may be used to obtain thoracic measures and determine pectus severity. However, for 3D images/scans to be used as a diagnostic tool in the proces of clinical decision making and determine surgical candidacy, its diagnostic accuracy should be evaluated. This will be investigated utilizing a pilot study design as no prior accuracy studies are available.

Detailed Description

This single-centre prospective pilot study is conducted to assess the diagnostic accuracy of 3D optical surface imaging based external Haller Index (EHI) measurements to quantify the severity of pectus excavatum. CR and CT based conventional Haller Indices (HI) are used as reference method.

CR and CT are both used as reference method, as the work-up of pectus patients in our centre is dependent of age. Subsequently, two groups are created: (A) patients under 18 years of age that receive a frontal (anteroposterior) and sagittal chest radiography, and (B) patients aged 18 years or older that receive a chest CT scan.

In this study, patients are their own control. To obtain optical surface images, a handheld 3D scanner is used. During acquisition, subjects will be standing in an upright position with arms abducted. Standard routinely used protocols are used to acquire chest radiographies and CT scans.

The HI is obtained from all chest radiographies and CT scans, calculated by dividing the widest thoracic transverse diameter by the anteroposterior distance, measured from the posterior surface of sternum to the anterior surface of the vertebral body. The EHI, a modified measurement to assess pectus deformity, is used to quantify PE severity based on 3D optical surface images. The EHI is calculated by dividing the widest external thoracic transverse diameter by the distance between the external deepest point or point of maximal protrusion and external vertebral body. The EHI is also calculated from the available chest radiographies and CT scans.

All measurements will be performed by three blinded observers that are not responsible to perform a comprehensive interpretation of the study. Following acquisition of all indices, the inter-observer reliability is calculated using the intraclass correlation coefficient. Based on the means, a receiver-operating characteristic (ROC)-curve is created for the 3D scan based EHI measurements, utilizing the surgical indication based on CR and CT (HI larger or equal to 3.25) images as gold standard. The optimal cut-off value, obtained from the ROC-curve is subsequently used to determine the 3D optical surface images' diagnostic accuracy.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
28
Inclusion Criteria

Not provided

Exclusion Criteria

Not provided

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Patients aged 18 years or olderCT scanGroup B consists of patients that receive a CT scan in the current work-up of PE.
Patients under 18 years of age3D optical surface imageGroup A consists of patients that receive a chest radiography in the current work-up of PE.
Patients aged 18 years or older3D optical surface imageGroup B consists of patients that receive a CT scan in the current work-up of PE.
Patients under 18 years of ageChest radiographyGroup A consists of patients that receive a chest radiography in the current work-up of PE.
Primary Outcome Measures
NameTimeMethod
Diagnostic accuracy of the EHI, calculated from 3D optical surface images1 year

Dependent of age, the CR or CT based HI is utilized as reference method

Secondary Outcome Measures
NameTimeMethod
Correlation of CT and CR derived HI with 3D optical surface image derived EHI1 year

Correlation is assessed by the Pearson's correlation coefficient

Inter-observer reliability1 year

Inter-observer reliability of CR, CT and 3D image derived (external) Haller Inidices, obtained by 3 observers

Correlation of CT scan derived EHI and 3D optical surface image derived EHI1 year

Correlation is assessed by the Pearson's correlation coefficient

Absolute agreement of CT scan derived EHI and 3D optical surface image derived EHI1 year

Assessed by the intraclass correlation coefficient

Correlation of CT scan derived HI and EHI1 year

Correlation is assessed by the Pearson's correlation coefficient

Trial Locations

Locations (1)

Zuyderland Medical Centre

🇳🇱

Heerlen, Limburg, Netherlands

© Copyright 2025. All Rights Reserved by MedPath