The PSIQS Study - User Experience With the Pro-Set Over Intended Wear of 3 Days With New Instructions and Requirement to be Inserted With the Quick-Serter

Becton, Dickinson and Company0 个研究点开始时间: 2017年9月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
撤回
主要终点
Compare Pro-set® vs. Quick-set® for non-inferiority for set insertion failures (set removal) due to either occlusion alerts or hyperglycemia

研究概览

简要总结

Open label, randomized 2-period cross-over study comparing two continuous subcutaneous insulin infusion sets ; MiniMed® Pro-set® with BD FlowSmart™ technology and MiniMed® Quick-set®

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Other
盲法
None

入排标准

年龄范围
13 Years 至 70 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Must be between 13 and 70 years of age (inclusive)
  • •Must have been previously diagnosed with type 1 diabetes mellitus
  • •Must be using one of the following Medtronic insulin pumps with the Paradigm connector (note 670G excluded) for at least 6 months prior to enrollment. These pumps must have the ability to upload data to Medtronic CareLink Therapy Management software.
  • •MiniMed Paradigm Revel™ Insulin Pump - models 523 (1.8 mL reservoir) and 723 (3 mL reservoir)
  • •MiniMed 530G Pump - models 551 (1.8 mL reservoir) and 751 (3 mL reservoir)
  • •MiniMed 630G System
  • •Must have been using the Medtronic Enlite CGM for at least 3 months prior to enrollment, and are currently doing so
  • •Must routinely insert their own infusion set (may be inserted manually or with an inserter or with an integrated set/inserter, i.e. Mio)
  • •If instructed, must be willing to insert all assigned infusion sets with a mechanical inserter
  • •Must have another form of insulin delivery available (i.e. vial and syringe or pen and pen needle)
  • •Must agree to continue using current Medtronic Enlite CGM throughout the study
  • •Willing to have insulin pump, BGM and CGM data downloaded into Medtronic CareLink Therapy Management Software (requires subject CareLink logon ID and password)
  • •In stable health status with no acute or significant illness, in the opinion of the investigator or designee
  • •Able to read, write and follow instructions in English
  • •Able and willing to provide informed consent
  • •Able and willing to comply with study procedures

排除标准

  • •Pregnant (self-attestation) or nursing
  • •Currently using a body-worn patch insulin infusion pump, e.g. Omnipod or V-Go
  • •Currently using the Medtronic Model 670G pump and associated CGM
  • •Current or past participation in previous BD Study DBC-16SCARL21
  • •History of bleeding disorder or easy bruising.
  • •Currently taking anti-platelet therapy or anticoagulants (use of up to 81 mg per day of aspirin is permitted).
  • •Known blood borne infections.
  • •History of recurrent dermatological condition or skin disorder (e.g. psoriasis, eczema, pre-existing dermatitis).
  • •Skin abnormalities, anomalies or conditions (e.g. sunburn, tattoos, extensive scarring, lipohypertrophy) located at or very close to the intended insertion site.
  • •Physical condition that restricts dexterity and may limit ability to perform study procedures (i.e. severe neuropathy or arthritis of the hands; self-reported)
  • •Currently participating in any other clinical investigation that conflicts with this study
  • •Employed by, or currently serving as a contractor or consultant to BD, Medtronic or study site
  • •Any other condition the investigator or designee deems to pose an unacceptable risk to the subject in the study

研究组 & 干预措施

Pro-set® vs. Quick-set®

Experimental

Subjects will be randomized to start with one of the study subcutaneous insulin administration sets (MiniMed® Pro-set® or MiniMed® Quick-set®). After completing the first study period,subjects will be placed in the alternative group according to the cross-over study design.

干预措施: MiniMed® Pro-set® (Device)

Pro-set® vs. Quick-set®

Experimental

Subjects will be randomized to start with one of the study subcutaneous insulin administration sets (MiniMed® Pro-set® or MiniMed® Quick-set®). After completing the first study period,subjects will be placed in the alternative group according to the cross-over study design.

干预措施: MiniMed® Quick-set® (Device)

结局指标

主要结局

Compare Pro-set® vs. Quick-set® for non-inferiority for set insertion failures (set removal) due to either occlusion alerts or hyperglycemia

时间窗: 6 hours from time of insertion

次要结局

  • Compare Pro-set® vs. Quick-set® for set removals due to hyperglycemia; > 400mg/dl.(6 hours from time of insertion)
  • Compare Pro-set® vs. Quick- set® for duration of wear(% reaching 12 hours, % reaching 24 hours, % reaching 36 hours, % reaching 48 hours, % reaching 60 hours, and % reaching 72 hours))
  • Compare Pro-set® vs. Quick- set® for set removals due to set failure; hyperglycemia >250mg/dl.(72 hours of set wear that occurs at 6 hours or later after insertion)
  • Compare Pro-set® vs. Quick- set® for set removals at less than 60 hours post insertion.(60 hours post insertion)