The Effect of Different Head and Trunk Positions on SVV in Healthy Individuals

Not Applicable
Completed
Conditions
Virtual Reality
Interventions
Diagnostic Test: SVV test
Registration Number
NCT05069701
Lead Sponsor
Pamukkale University
Brief Summary

Aim: To obtain standardization data in static virtual SVV and dynamic virtual SVV tests according to different head and body positions by keeping up with developing technologies. In this way, it is planned to evaluate the treatment responses of patients who receive vestibular rehabilitation in a healthier way.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
120
Inclusion Criteria
  1. Healthy adult volunteers
  2. Volunteers over 18 years old
Exclusion Criteria
  1. Patients with impaired cooperation
  2. Musculoskeletal or systemic presence of disease
  3. Past ear disease
  4. Patients who have experienced dizziness
  5. Presence of central nervous system pathology
  6. Patients who have used ototoxic drugs
  7. Patients whose use of glasses may cause problems (epilepsy, vision loss, etc.)

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Healthy volunteersSVV testSVV test will be done.
Primary Outcome Measures
NameTimeMethod
Static SVV test1 month

For commercially available VR Subjective Visual vertical(SVV), VIRTUALIS® PHYSIO VR\[SVV and Dynamic SVV\](Virtualis, France) was used. The bar angles are given in a random order. The system consists of glasses, computer and hand control. When patients wear their glasses, they can see only a light bar in Static SVV, and points rotating left or right on the background of the light bar in Dynamic SVV. No light can enter the glasses. The glasses have a sensor that detects the angle of the head. The starting point of the bar can be adjusted randomly to different angles by the computer. The visual background rotation rate for dynamic SVV was determined as ±30°/sec. The subject should adjust the bar in the vertical position using the right/left arrows on the controller. When verticality is confirmed by pressing the set button in the middle of the control unit, the computer records the angle of the bar and the position of the head.

Dynamic SVV test1 month

For commercially available VR Subjective Visual vertical(SVV), VIRTUALIS® PHYSIO VR\[SVV and Dynamic SVV\](Virtualis, France) was used. The bar angles are given in a random order. The system consists of glasses, computer and hand control. When patients wear their glasses, they can see only a light bar in Static SVV, and points rotating left or right on the background of the light bar in Dynamic SVV. No light can enter the glasses. The glasses have a sensor that detects the angle of the head. The starting point of the bar can be adjusted randomly to different angles by the computer. The visual background rotation rate for dynamic SVV was determined as ±30°/sec. The subject should adjust the bar in the vertical position using the right/left arrows on the controller. When verticality is confirmed by pressing the set button in the middle of the control unit, the computer records the angle of the bar and the position of the head.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Pamukkale University

🇹🇷

Denizli, Turkey

© Copyright 2025. All Rights Reserved by MedPath