Retrospective Study on Clinical Performance and Safety Profile of MJ-Flex Elastic Nail
- Conditions
- Fractures, Bone
- Interventions
- Device: MJ-Flex The New Metaizeau Nail
- Registration Number
- NCT06412913
- Lead Sponsor
- Orthofix s.r.l.
- Brief Summary
This study aims to retrospectively collect data from routine clinical practice in order to evaluate the safety profile of the MJ-FLEX elastic nail used in pediatric patients according to the manufacturer Instructions For Use (IFU) in the time frame from the time of surgery until the last follow-up visit available at the hospitals.
- Detailed Description
The study is planned to be conducted in two investigational sites, one in France and one in United Kingdom, both experienced in the treatment of pediatric patients with diaphyseal fractures in the clavicle and in upper and lower limbs, where the usage of MJ-Flex The New Metaizeau Nail (known as MJ-Flex) was part of the normal clinical practice.
Investigator of both study sites will provide data for a maximum of 61 patients meeting inclusion and exclusion criteria (Considering a drop-out or a non-evaluable rate of 10% of the procedures) that will contribute for approximately 61 procedures in which MJ-Flex was used.
No diagnostic or therapeutic intervention outside of routine clinical practice will be applied. The study has been designed to analyze medical records of patients where study data was collected as part of their routine clinical practice. Therefore, patients will be retrospectively enrolled in the study. Patients who have undergone MJ-Flex implantation from 02/2018 to 12/2022 are considered for the study The observation period of study subjects will comprise from surgery until the last follow up visit available.
Medical records of the participating sites are expected to contain all the required information.
In United Kingdom, no study visit will be required but according to local legislation, it will be essential that before collecting any information from medical records, participants or their guardians are asked for specific informed consent to be signed by them before any collection of patient information takes place.
However, in France, due to the use of primary data and the foreseen exemption of the informed consent (IC) form (see Section 14.2 Informed Consent), no study visit will be required.
Recruitment & Eligibility
- Status
- TERMINATED
- Sex
- All
- Target Recruitment
- 6
- The patient has been adequately informed by providing the PIS. 1.1 The patient expressed his willingness to participate in the Study by signing and dating informed consent (valid only for UK patients according to local law).
- Patients who had a regular indication for surgical intervention with MJ-Flex according to the manufacturer's IFU.
- Patients in pediatric age (> 18 month and < 18 years) at the time of surgery.
- Patients skeletally immature.
- Patients who underwent surgery performed with MJ-Flex.
- Patients with clinical data registered in her/him medical records sufficient to assess the safety and efficacy endpoint of the study: in particular, the patient has at least one follow-up at minimum 3 months from the surgery where is possible for the investigator to assess the consolidation of the treated bone.
- The patient had surgery at least 1 year before enrollment.
- Patient who had/has a medical condition that is a contraindication according to the manufacturer's instruction for use leaflet.
- Patient who had/has a concomitant not permitted device which cannot be safely removed.
- Patient for whom there are other concurrent medical or other conditions that in the opinion of the participating investigator may prevent participation or otherwise render the patient ineligible for the study.
- The patient had surgery less than 1 year before enrollment.
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Patients in pediatric age (> 18 month and < 18 years) at the time of surgery MJ-Flex The New Metaizeau Nail The full analysis set includes all paediatric patients who that have been treated for diaphyseal fractures of long bones with the MJ-FLEX the will be systematically consecutive screened at the centers.
- Primary Outcome Measures
Name Time Method Percentage of procedures that have achieved bone union at the "bone consolidation assessment" visit After 5 month (approximately) from surgery The measurement of efficacy will be mande with the percentage of procedures that have achieved bone union
Percentage of procedures with at least one serious/not serious adverse event certainly related or possibly related to MJ-FLEX (ADEs/SADEs) from the date of surgery until the last follow-up, assessed up to 1 year This outcome will be used to measure safety
Percentage of procedures who experienced at least one MDDs that caused an effect on the patient from the date of surgery until the last follow-up, assessed up to 1 year This outcome will be used to measure safety
Post-treatment fracture-free survival up to 1 year This outcome will be used to measure safety
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Sheffield Children's NHS Foundation Trust
🇬🇧Sheffield, United Kingdom