Comparison of 133Xe Scintigraphy With 19F MRI

Early Phase 1
Withdrawn
Conditions
Lung Diseases
Registration Number
NCT03532334
Lead Sponsor
Hal C Charles
Brief Summary

The central hypothesis and current observation is that PFx gases used as contrast agents readily provide functional images of the lung airways including important regional ventilation information such as ventilation defect severity and gas trapping. This is a pilot proof of concept study to demonstrate the non-inferiority of 19F MRI gas Ventilation imaging compared to 133Xe ventilation Scintigraphy in subjects with lung disease. The secondary goal of the study is to develop sufficient information to adequately power a pivotal trial of 19F MRI gas Ventilation imaging compared to 133Xe Ventilation Scintigraphy

Detailed Description

Aim 1: Compare measures of lung ventilation performance obtained using 133Xe Scintigraphy with performance using 19F Perfluorinated gas MRI using two independent readers.

133Xe Scintigraphy will be scored using the methods described in the statistics section and 19F images will be scored using the methods described in the statistics section. Scores for each subject will be earluated for consistency between readers and modalities. 60% concordance will be considered equivalent.

The outcomes of the work proposed is expected to show the non-inferiority of 19F Perfluorinated gas MRI to 133Xenon Scintigraphy

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria

Subjects must meet all of the following inclusion criteria to be eligible for enrollment into the trial

  1. Outpatients of either gender, age > 18.
  2. Willing and able to give informed consent and adhere to visit/protocol schedules. (Consent must be given before any study procedures are performed.)
  3. Women of childbearing potential must have a negative urine pregnancy test. This will be confirmed before participation in this investigational protocol.
  4. Completion of 133Xe ventilation scintigraphy after referral for ventilation imaging for any reason in Pro00081987 A Comparison of Technegas® and Xenon 133 Planar Lung Imaging in Subjects Referred for Ventilation Scintigraphy. The MRI will be accomplished in a timely fashion after the Scintigraphy study based on scheduling availability in the Center for Advanced Magnetic Resonance Development (CAMRD).
Exclusion Criteria

Subjects presenting with any of the following will not be included in the trial:

  1. Conditions that will prohibit MRI scanning (metal in eye, claustrophobia, inability to lie supine)

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Primary Outcome Measures
NameTimeMethod
Efficacy of 19F MRI compared to 133 Xenon Scintigraphy24 months

To evaluate the non-inferiority of 19F Perfluorinated gas MRI compared to 133 Xenon Scintigraphy ventilation imaging studies two readers will be selected as having experience reading Xe-133 ventilation scans. Readers will also receive training on interpretation of 19F ventilation images We note that the nature of the images both nuclear medicine and 19F MRI preclude blinding of the readers to the image modality. Images from each modality will be assessed independently and the images will be coded so that readers will not know which image set is from each subject.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Duke University Medical Center

🇺🇸

Durham, North Carolina, United States