Thoracoscopic Versus Endocardial Ablation in Patient With Paroxysmal AF After Failed Initial Endocardial Ablation
Phase 2
Completed
- Conditions
- Paroxysmal Atrial Fibrillation
- Interventions
- Procedure: Thoracoscopic epicardial ablationProcedure: Endocardial catheter ablationDevice: Implantable loop recorder
- Registration Number
- NCT01794416
- Lead Sponsor
- Meshalkin Research Institute of Pathology of Circulation
- Brief Summary
The investigators aimed to compare two approaches thoracoscopic epicardial ablation and endocardial catheter ablation after failed initial catheter ablation in patients with paroxysmal atrial fibrillation.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 50
Inclusion Criteria
- failed initial catheter ablation
- paroxysmal atrial fibrillation
Exclusion Criteria
- chronic lung disease
- body mass index >35
- longstanding atrial fibrillation 1 year
- previous stroke or transient ischemic attack
- left atrial thrombus
- left atrial size >65 mm
- left ventricular ejection fraction <35%
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Thoracoscopic epicardial ablation Thoracoscopic epicardial ablation Patients were treated with video-assisted thoracoscopy under general anesthesia. PVI was performed from the epicardial side with a bipolar RF ablation clamp (AtriCure). At least 2 overlapping applications around each of the ipsilateral veins were made, and isolation was confirmed by the absence of PV potentials and exit block during pacing. An additional application was made in the interatrial Waterston groove in the right side to isolate the ganglionic plexi from the atria. On the left side, the ligament of Marshal was cut, but no additional ablation of ganglionic plexi was pursued. The RevealXT (implantable loop recorder) was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. Thoracoscopic epicardial ablation Implantable loop recorder Patients were treated with video-assisted thoracoscopy under general anesthesia. PVI was performed from the epicardial side with a bipolar RF ablation clamp (AtriCure). At least 2 overlapping applications around each of the ipsilateral veins were made, and isolation was confirmed by the absence of PV potentials and exit block during pacing. An additional application was made in the interatrial Waterston groove in the right side to isolate the ganglionic plexi from the atria. On the left side, the ligament of Marshal was cut, but no additional ablation of ganglionic plexi was pursued. The RevealXT (implantable loop recorder) was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. Endocardial catheter ablation Endocardial catheter ablation Externally-irrigated tip (5-mm tip, Celsius Thermo-Cool, Biosense Webster, Diamond Bar, CA, USA). Temperature-controlled RF delivery was performed with a maximum power output of 50 W and temperature limit of 50 C. The catheter was irrigated using 0.9% saline infusion at a flow rate of 20-40 mL/min during RF delivery and 2 mL/min between applications using a commercially available pump (Cool Flow, Biosense Webster). The RevealXT (implantable loop recorder) was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. Endocardial catheter ablation Implantable loop recorder Externally-irrigated tip (5-mm tip, Celsius Thermo-Cool, Biosense Webster, Diamond Bar, CA, USA). Temperature-controlled RF delivery was performed with a maximum power output of 50 W and temperature limit of 50 C. The catheter was irrigated using 0.9% saline infusion at a flow rate of 20-40 mL/min during RF delivery and 2 mL/min between applications using a commercially available pump (Cool Flow, Biosense Webster). The RevealXT (implantable loop recorder) was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.
- Primary Outcome Measures
Name Time Method freedom from any atrial arrhythmia 12 months
- Secondary Outcome Measures
Name Time Method rate of significant adverse events (SAEs) 12 months atrial fibrillation burden by ILR 12 months
Trial Locations
- Locations (1)
State Research Institute of Circulation Pathology
🇷🇺Novosibirsk, Russian Federation