MedPath

A Comparison of Large Diameter Metal Heads vs. Small Diameter Metal Heads vs/ Dual Mobility Total Hip Replacements

Completed
Conditions
Total Hip Replacement
Interventions
Other: Metal Ion Levels
Registration Number
NCT02049892
Lead Sponsor
Mayo Clinic
Brief Summary

Does having a large diameter metal on polyethylene total hip replacement increase metal ion release. Larger metal heads are thought to have increased torsional forces on the trunion which would like release more metal ions. Increased metal ion levels have been associated with adverse local tissue reactions. Are there any differences comparing these groups to a dual mobility type total hip replacement.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
80
Inclusion Criteria
  • One total hip replacement, either a large metal head (>40) or a small metal head (<30) on a polyethylene bearing surface.
  • 2 to 5 years s/p surgery minimum. No symptoms
Exclusion Criteria
  • Any other bearing surface besides metal on poly, no other joint replacements, symptomatic

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Metal IonMetal Ion Levels-
Primary Outcome Measures
NameTimeMethod
Metal Ion levels2 years

We would like to determine a difference in metal ion levels on metal on polyethylene total hip replacement

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Mayo Clinic

🇺🇸

Rochester, Minnesota, United States

© Copyright 2025. All Rights Reserved by MedPath