跳至主要内容
临床试验/NCT02736422
NCT02736422已完成1 期

Assessment of New Magnetic Resonance Imaging (MRI) Pulse Sequences for Imaging Hyperpolarised Xenon in Lung, Heart and Brain in Volunteers

Sheffield Teaching Hospitals NHS Foundation Trust2 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2011年7月最近更新:
适应症

试验速览

阶段
1 期
状态
已完成
入组人数
40
试验地点
2
主要终点
Qualitative assessment of images 3

研究概览

简要总结

Hyperpolarised gas Magnetic resonance imaging (MRI) (Hyperpolorised 3He and 129Xe MRI) provides novel regional functional images of the lungs. Over the past 14 years researchers at Sheffield Teaching Hospitals NHS Foundation Trust and University of Sheffield have been developing and evaluating different MRI techniques to investigate different aspects of the lung function with both Hyperpolorised 3He and more recently 129Xe gas and have tested these new methods in volunteers with healthy and diseased lungs. This proposed study is to further test the sensitivity of MRI pulse sequences with inhaled 129Xe gas in volunteers. This protocol serves to evaluate the sensitivity of pulse sequences for 129Xe magnetic resonance imaging in the lungs and monitoring the transient changes in vital signs during and following the gas inhalation. This includes evaluation of pulse sequences to image xenon in the heart and brain as well as in the lungs of volunteers.

详细描述

The primary endpoints are to test the pulse sequences under development to image lung ventilation and perfusion, cardiac perfusion and brain uptake of xenon

The study will seek to test the given pulse sequence under investigation in a group of up to 40 volunteers.

To be eligible, each subject will have no contraindications to MRI scanning and will have signed the necessary volunteer consent forms.

The target recruitment number should provide sufficient data to determine the efficacy of the techniques under development.

Methods HP 129Xe MRI scans will be performed. MRI images will be acquired with the patients supine inside a 129Xe-capable MRI system, (1.5 Tesla GE, USA or 3.0 Tesla Philips, Netherlands), using dedicated transmit-receive radio-frequency coils.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age greater than 18, less than
  • NB: Participants will also be permitted to take part in study STH15080 (Eudract number 2009-010815-34, 'Development of new Magnetic resonance imaging (MRI) pulse sequences for probing lung function in volunteers with hyperpolarised 3He gas').

排除标准

  • Contraindication to MRI.
  • Resting oxygen saturation less than 90%.
  • Known disease of the lungs, heart or brain.
  • Pregnant.
  • Volunteer eligibility will be determined by completion of the study screening form not by physical examination or testing. Eligibility will be confirmed by a clinician upon review of the study screening form, prior to completing the study prescription for xenon dosing.

结局指标

主要结局

Qualitative assessment of images 3

时间窗: Baseline

presence of artifacts

Qualitative assessment of images 2

时间窗: Baseline

spatial resolution

Qualitative assessment of images 1

时间窗: Baseline

signal to noise ratio,

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验