临床试验/NCT03586583
NCT03586583已完成不适用

A Feature Comparison Study to Evaluate the Modified Processing of Fujifilm's ASPIRE Cristalle With Digital Breast Tomosynthesis Option as Compared to the Original Processing

Fujifilm Medical Systems USA, Inc.1 个研究点 分布在 1 个国家目标入组 600 人开始时间: 2018年6月30日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
600
试验地点
1
主要终点
Comparison of ISR (Modified Processing) to FBP (Original Processing)

研究概览

简要总结

The purpose of the feature comparison study is to evaluate general mammographic features in images of the same breast when reconstructed with modified (ISR and DVIIm) processing as compared to the original processing (FBP with EDR and MFP).

详细描述

This clinical research is a retrospective, feature comparison reader study with an enriched sample of 600 (100 per radiologist) breast screening or diagnostic cases which were selected from the library of mammograms collected under Fujifilm protocol FMSU2013-004A (all subjects previously provided written informed consent agreeing their image data and supporting documentation could be used for future research and investigations).

Six MQSA-qualified and board-certified mammographers representing various experience levels, will be shown DBT images of a breast with the modified processing side-by-side the same breast with the original processing on the ASPIRE Bellus II workstation.. One breast per subject (two views per breast; CC and MLO) will be evaluated by the readers. Readers will be blinded to the image reconstruction and presentation processing methods. Each reader will be given a different sample of cases to review. Approximately 600 total cases (100 cases per reader) will compose the sample. The order of the subjects and location (left or right review workstation high resolution monitor) of the images with modified processing will be randomized for each reader.

The primary objective is the readers' assessment for each of the 7 general mammographic features. The null hypothesis is that the pooled proportion of cases judged as non-inferior with modified image processing is <0.50, versus the alternative hypothesis that the pooled proportion is >0.50. If the 95% CI does not contain values <0.50, then the null hypothesis will be rejected. These hypotheses will be evaluated for each of the 7 general mammographic features. If all 7 null hypotheses are rejected, then it will be concluded that the modified imaging features are non-inferior to the original imaging

研究设计

研究类型
Observational
观察模型
Case Crossover
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Female subjects participating in FMSU2013-004A protocol with known clinical status

排除标准

  • Female subjects that did not have known clinical status in FMSU2013-004A

结局指标

主要结局

Comparison of ISR (Modified Processing) to FBP (Original Processing)

时间窗: 1 day reading session

For each reader, the cases judged as non-inferior with modified processing will be calculated for each feature and each view. Non-inferiority will be defined as a score of equivalence between modified and original or a score indicating the modified image processing is superior. Readers compared several general mammographic features using the following 5-point scale: negative 2 (left image much superior) negative 1 (left image somewhat superior) 0 (left and right images are equivalent) positive 1 (right image somewhat superior) positive 2 (right image much superior)

次要结局

未报告次要终点

研究者

发起方
Fujifilm Medical Systems USA, Inc.
申办方类型
Industry
责任方
Sponsor