MedPath

Vanguard™ Deep Dish Rotating Platform Knee Clinical Evaluation

Not Applicable
Completed
Conditions
Osteoarthritis
Interventions
Device: Vanguard™ Deep Dish Rotating Platform Knee
Device: Vanguard™ Cruciate Retaining Knee
Registration Number
NCT00753090
Lead Sponsor
Zimmer Biomet
Brief Summary

This study is being conducted on the Vanguard™ Deep Dish Rotating Platform (DD RP) to evaluate the clinical efficacy of the DDRP components.

Detailed Description

This study is designed to evaluate the safety and efficacy of Vanguard™ Deep Dish Rotating Platform Knee (mobile bearing knee) as compared to Vanguard Cruciate Retaining Knee (fixed bearing knee). This trial was conducted as the randomised, controlled study.

Implant loosening and polyethylene wear in fixed-bearing knee prostheses were recognized as major causes of late failure. The mobile bearing knee have the theoretical advantages of potentially minimizing the polyethylene wear and reducing implant to bone interface stress in order to reduce the incidence of implant loosening. Therefore, the aims of this study were to prove the Vanguard deep dish rotating platform knee is at least as effective in clinical outcome as the widely used current design of knee replacement and better in long term survivorship.

The efficacy of the device was determined by the relief of pain, restoration of function and range of motion. The durability of device was determined by the absence of revision/removal and radiological integrity. To assess the safety of the device, all post operative complications were recorded either device related or otherwise. Patient satisfaction was determined by answers to patient outcome questionnaires (Oxford Knee Score, WOMAC and Lower Extremity Activity Scale).

Between June 29, 2009 and March 5th 2012, 326 cases were enrolled in the study. In total 117 cases were implanted with the Vanguard fixed bearing cruciate retaining knee; the control arm, and 209 cases were implanted with the Vanguard DDRP. All of these patients fulfilled the inclusion/exclusion criteria. From the 4 participating sites, 2 of them (both located in the Netherlands, Zuyderland Hospital and Bravis Hospital) performed a randomized controlled trial (RCT). In the RCT, 40 cases were assigned to the Trial Arm (Vanguard DDRP), and 51 to the control arm (Vanguard CR). The UK site enrolled cases only in the Vanguard DDRP arm and the French site enrolled in both arms, but non-randomized. Total 326 patients are enrolled in the study.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
326
Inclusion Criteria
  • Patients with a pre-operative Knee Society Score of < 70
  • Patients scheduled to undergo primary total knee replacement with any of the following indication: Painful and disabled knee joint resulting from osteoarthritis, Traumatic Arthritis, Rheumatoid Arthritis; One or more compartments are involved
  • Need to obtain pain relief and improve function
  • Ability and willingness to follow instructions, including control of weight and activity level, and to return for follow-up evaluations
  • A good nutritional state of the patient
  • Full skeletal maturity of the patient, patients who are at least 18 years of age
  • Patients of either sex
  • Consent form read, understood, and signed by patient
Exclusion Criteria

Absolute contraindications include the following diagnoses:

  • Patients with a pre-operative Knee Society Score of >= 70
  • Infection
  • Osteomyelitis
  • Previous partial or total prosthetic knee replacement on the operative side
  • Patients who are less than 18 years of age
  • Sepsis
  • Patients who had body mass index >= 40

Relative contraindications include the following factors:

  • Uncooperative patient or patient with neurological disorders who are incapable of following directions or who are predictably unwilling to return for follow-up examinations
  • Osteoporosis or marked bone loss, which may preclude proper fixation of the prosthesis
  • Metabolic disorders, which may impair bone formation
  • Osteomalacia
  • Distant foci of infections, which may spread to the implant site
  • Rapid joint destruction, marked bone loss, or bone resorption apparent on roentgenogram
  • Vascular insufficiency, muscular atrophy, or neuromuscular disease in the affected limb.
  • Incomplete or deficient soft tissue surrounding the knee

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
VG DDRPVanguard™ Deep Dish Rotating Platform KneeThis arm utilizes the Vanguard™ Deep Dish Rotating Platform Knee.
VG CRVanguard™ Cruciate Retaining KneeThis arm utilizes the Vanguard™ Cruciate Retaining Knee.
Primary Outcome Measures
NameTimeMethod
Knee Society Score2 years

The Knee Society Score (KSS) is a clinician-completed questionnaire and consists of two sub-scores: an Objective score assessing pain, range of motion, anteroposterior and mediolateral stability, along with deductions for higher than normal flexion contracture, extension lag and/or varus/valgus alignment, and a Function score, assessing walking on level ground and walking up and down stairs, along with deductions for support. Each sub-score can range from 0 to 100 points, with higher scores corresponding to better outcomes, classified as Excellent: 80 - 100 points; Good: 70 - 79 points; Fair: 60 - 69 points; Poor: \< 60 points.

Secondary Outcome Measures
NameTimeMethod
Survivorship10 years

implant survival at 10 years post surgery and is presented by the number of cases with the implants unrevised

Knee Society Score6 weeks, 6 months, annually until all available study patients have completed two-year follow up evaluation and alternating odd years or as needed thereafter up to 10 years

The Knee Society Score (KSS) is a clinician-completed questionnaire and consists of two sub-scores: an Objective score assessing pain, range of motion, anteroposterior and mediolateral stability, along with deductions for higher than normal flexion contracture, extension lag and/or varus/valgus alignment, and a Function score, assessing walking on level ground and walking up and down stairs, along with deductions for support. Each sub-score can range from 0 to 100 points, with higher scores corresponding to better outcomes, classified as Excellent: 80 - 100 points; Good: 70 - 79 points; Fair: 60 - 69 points; Poor: \< 60 points.

Radiographic Evaluation: Total Varus Angle6 weeks, 6 months, 1, 2, 3, 5, 7, and 10 years postoperative

Assessment of patient x-rays by each site investigator: Total varus angle. This is defined as the sum of the femoral flexion (the angle between the femoral median axis and the tibial median axis) and the tibial angle (the angle between the anatomical axis of the femur and the tibia in the anteroposterior view of the knee joint) minus 180 degrees.

Radiographic Evaluation: Radiolucency6 weeks, 6 months, 1, 2, 3, 5, 7 and 10 years postoperative

Assessment of patient x-rays by each site investigator: Radiolucency Femoral Radiolucency is defined as the total nr of participants with radiolucency measured on the femur in each of the 7 different zones.

Tibia AP Radiolucency is defined as total nr of participants with radiolucency in each of the 7 zones measured in the AP view X-ray Tibia lateral Radiolucency defined as total nr of participants with radiolucency in each of the 3 zones in the lateral view X-ray Patella Radiolucency is defined as total nr of participants with radiolucency in each of the 5 zones

Trial Locations

Locations (4)

CHU Lyon Sud

🇫🇷

Pierre Benite, France

The Hillingdon Hospital NHS Trust

🇬🇧

Middlesex, United Kingdom

Zuyderland Medisch Centrum Sittard-Geleen

🇳🇱

Sittard, Netherlands

Bravis Ziekenhuis

🇳🇱

Roosendaal, Netherlands

© Copyright 2025. All Rights Reserved by MedPath