跳至主要内容
临床试验/NCT06333327
NCT06333327招募中不适用

Multielectrode Radiofrequency Balloon for Atrial Fibrillation Catheter Ablation: A Multicenter Real-World Experience

Universitair Ziekenhuis Brussel1 个研究点 分布在 1 个国家目标入组 2,000 人开始时间: 2021年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
2,000
试验地点
1
主要终点
Atrial arrhythmia recurrence after ablation

研究概览

简要总结

All consecutive patients with paroxysmal or persistent atrial fibrillation undergoing pulmonary vein isolation with the radiofrequency balloon catheter (RFB) "Heliostar" (Biosense Webster) will be included in a multicenter observational registry. The aim of the study is to assess the safety and arrhythmic outcome of atrial fibrillation ablation with the RFB in a real-world setting.

详细描述

All consecutive atrial fibrillation patients undergoing pulmonary vein isolation (PVI) with the novel radiofrequency balloon catheter (RFB) "Heliostar" (Biosense Webster) will be prospectively included in a multicenter observational registry.

PVI with the RFB will be performed as previously described. Briefly, after optimal RFB positioning, confirmed through the correct alignment between the RFB and the pulmonary vein and sufficient electrode-tissue contact, ablation is performed in temperature-controlled mode with unipolar radiofrequency energy. Typically, >2 posterior electrodes are identified on the RFB. The power setting is 15 W and the target electrode temperature is 55° C. The same energy is simultaneously delivered to all electrodes, with a duration of 15-20 s for the posterior and 45-60 s for the non-posterior electrodes. During ablation, pulmonary vein potentials are monitored on the circular diagnostic catheter to evaluate real-time isolation. In the case of pulmonary vein acute reconnection, additional applications are delivered to achieve durable PVI. An esophageal temperature probe will be used to monitor any increase in esophageal temperature.

Follow-up will be performed according to each standard institutional protocol.

Safety endpoints include any major periprocedural complications [e.g. death, atrioesophageal fistula, stroke/transient ischaemic attack, pericardial effusion/tamponade with/without surgical treatment, myocardial infarction, and persistent phrenic palsy] occurring within 7 days post-procedure (except for atrioesophageal fistula). Minor complications will also be reported, including vascular access complications requiring treatment, pericarditis, and transient phrenic palsy.

Efficacy outcome is defined as arrhythmia-free survival during the follow-up. Arrhythmia recurrence is defined as any atrial tachyarrhythmias ≥30 s after a 90-day post-ablation blanking period.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • symptomatic atrial fibrillation with indication to catheter ablation

排除标准

  • age <18 years old
  • pregnancy
  • any contraindications to catheter ablation

结局指标

主要结局

Atrial arrhythmia recurrence after ablation

时间窗: After 3 months post-ablation.

The primary outcome endpoint is defined as arrhythmia-free survival during the follow-up. Arrhythmia recurrence is defined as any atrial tachyarrhythmias ≥30 s after a 90-day post-ablation blanking period.

Procedural safety

时间窗: Up to 7 days post-procedure (except for atrioesophageal fistula or pulmonary vein stenosis)

The primary safety endpoint included any major periprocedural complications \[e.g. death, atrioesophageal fistula, stroke/transient ischaemic attack (TIA), pericardial effusion/tamponade with/without surgical treatment, myocardial infarction, and persistent phrenic palsy\] occurring within 7 days post-procedure (except for atrioesophageal fistula). Minor complications, including vascular access complications requiring treatment, pericarditis, and transient phrenic palsy will also be assessed.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Carlo de Asmundis

MD, PhD

Universitair Ziekenhuis Brussel

研究点 (1)

Loading locations...

相似试验