MedPath

Study to Determine the Difference in Reduction of Bioaerosols in a Long-term Care Facility

Not Applicable
Not yet recruiting
Conditions
Air Pollution
Interventions
Other: Use of C-Polar coated HVAC Filter versus conventional HVAC Filter
Registration Number
NCT06506890
Lead Sponsor
C-Polar Innovations
Brief Summary

This is a CONTROLLED PROSPECTIVE COHORT study of a long-term care facility. At the start of the study a dedicated section A of the facility ventilation system will have routine HVAC filters of the same dimensions installed, while section B of the same facility ventilation system will have C-POLAR (cationic polymeric coated) HVAC filters installed. There will be continuous Indoor Air Quality monitors (PM 2.5, CO2, VOC, Radon, Temp, and RH) installed at different vent locations throughout the long-term care facility for the duration of the study. Air samples with an Airport MD8 BAMS machine will be taken once a week at various vent locations at the long-term care facility.

Detailed Description

This is a CONTROLLED PROSPECTIVE COHORT study of a long-term care facility. At the start of the study a dedicated section A of the facility ventilation system will have routine HVAC filters of the same dimensions installed, while section B of the same facility ventilation system will have C-POLAR (cationic polymeric coated) HVAC filters installed. There will be continuous Indoor Air Quality monitors (PM 2.5, CO2, VOC, Radon, Temp, and RH) installed at different vent locations throughout Cottonwoods for the duration of the study. Air samples with an Airport MD8 BAMS machine will be taken once a week at various vent locations at the long-term care facility. The aim of this study is to determine the difference in reduction of bioaerosols in a long-term care facility with MERV 13 C-POLAR (cationic polymeric coated) HVAC filters compared to conventional MERV 13 HVAC filters.

Primary Endpoint:

This study aims to determine the reduction of bioaerosols (BAMS) in a facility with a C-POLAR HVAC filter building intervention versus conventional filters.

Secondary Endpoints:

1. Volatile organic compound (VOC)

2. Radon determination

3. Static, passive particulate determination from air

4. Air microbiome analysis

5. Air Quality and Respiratory Staff Survey

Radon gas testing, particulate matter testing (PM2.5) \[fine inhalable particles, with diameters that are generally 2.5 micrometers and smaller\]. Carbon dioxide testing (CO2), VOCs testing \[volatile organic compounds (airborne chemicals)\], relative humidity (RH) testing \[it is a measure of the actual amount of water vapor in the air compared to the total amount of vapor that can exist in the air at its current temperature\], and temperature readings.

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
100
Inclusion Criteria
  1. Any resident, staff, and any individual who enters the long term care facility will be in a broad sense, involved in this study, as the MERV 13 HVAC filters will be installed within the HVAC system and will not allow anyone to not participate in the study who enters the facility. It is impracticable to carry out this research of comparing two different HVAC filters in an active long term care setting by receiving prior consent from all individuals who may enter, such as vendors or visitors. This research involves no more than minimal risk and may or may not improve air quality or minimize bioaerosols in the facility.
Exclusion Criteria
  1. Does not wish to enter the long-term care facility until completion of study.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
comparing the difference in reduction of bioaerosols between HVAC filtersUse of C-Polar coated HVAC Filter versus conventional HVAC Filtercomparing the difference in reduction of bioaerosols between HVAC filters.
Primary Outcome Measures
NameTimeMethod
The primary endpoint is comparing the difference in reduction of bioaerosols between MERV 13 HVAC filters.Nine Months

The aim of this study is to determine the difference in reduction of bioaerosols in a long-term care facility with MERV 13 C-POLAR (cationic polymeric coated) HVAC filters compared to conventional MERV 13 HVAC filters.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Kelowna General Hospital

🇨🇦

Kelowna, British Columbia, Canada

© Copyright 2025. All Rights Reserved by MedPath