ACTRN12616001564448尚未招募不适用
Sigh35 and end-expiratory occlusion test to assess fluid responsiveness in critically ill patients undergoing pressure support ventilation: a validation study.
antonio messina0 个研究点目标入组 60 人开始时间: 2016年11月11日最近更新:
适应症
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 60
研究概览
简要总结
暂无简介。
研究设计
- 研究类型
- Interventional
- 分配方式
- Non-randomised trial
- 主要目的
- Diagnosis
入排标准
- 年龄范围
- 18 Years 至 o limit(—)
- 性别
- All
入选标准
- •1) Acute circulatory failure defined by a systolic arterial pressure less than or equal to 90 mm Hg (or fall of systolic arterial pressure of at least 50 mm Hg in known hypertensive patients) and one or more of the following signs: 1) urinary flow less than or equal to 0.5 mL/kg/min for greater than or equal to 2 hours, 2) tachycardia greater than or equal to 100 bpm, or 3) presence of skin mottling. 2) PSV with inspiratory support level (PS) between 8 and 15 cmH2O and positive end-expiratory pressure (PEEP) between 5 and 10 cmH2O; 3) stable ventilatory pattern.
排除标准
- •1) severe myocardial or valvular dysfunction; 2) cardiac arrhythmias; 3) severe acute respiratory distress syndrome (ARDS); 4) haemodialysis or continuous hemofiltration; 5) Body Mass Index equal or greater to 30; 6) altered arterial waveform; 7) diagnosis of pneumothorax.
研究者
相似试验
招募中
4 期
Mini fluid challenge (MFC) , administering 100 ml of fluid over 1 minute and end expiratory occlusion test (EEOT) (stopping respiration in the expiratory phase by using expiratory pause button in the ventilator)for Predicting which patients with acute circulatory failure will respond to fluidCTRI/2017/09/009936DR S Velmurugan100
Unknown
不适用
Sigh35 and End-expiratory Occlusion Test (EEOT) for Assessing flUid Responsiveness in Critically Ill Patients Undergoing Pressure Support VentilationCritically Ill PatientsHemodynamic InstabilityMechanical Ventilation Pressure HighNCT04924920Humanitas Clinical and Research Center60
招募中
Unknown
The use of End Expiratory Occlusion Test vs. Inferior Vena Cava Respiratory Variation for prediction of volume responsiveness in mechanically ventilated patients with sepsisAssessment of fluid responsiveness in septic shock patientsPACTR202306581320725Faculty of medicine Ain Shams university34
已完成
不适用
End-expiratory occlusion test using non-invasive test to predict fluid responsiveness in the operating theatreJPRN-UMIN000040159Jichi Medical University Saitama Medical Center41
已完成
不适用
Mini Fluid chAlleNge and End-expiratory Occlusion Test and to Assess flUid responsiVEness in opeRating RoomHemodynamic InstabilityAnesthesiaSurgeryNCT03808753Humanitas Clinical and Research Center103
