Skip to main content
Clinical Trials/NCT06007196
NCT06007196Not yet recruitingNot Applicable

Performance Evaluation of Non-invasive Continuous Hemodynamic Measurement From Task Force(R) CORE Versus Invasive Reference

Medical University of Vienna1 site in 1 country70 target enrollmentStarted: September 1, 2023Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Not yet recruiting
Enrollment
70
Locations
1
Primary Endpoint
Difference in intraoperative cardiac output measurements between Task Force CORE compared with thermodilution during surgery

Study Overview

Brief Summary

Validation of hemodynamic measurements using the non-invasive Task Force Core(R) and Task Force Cardio(R) device with invasive hemodynamic measurements using the thermodilution technique (PICCO device).

Detailed Description

The investigational device, Task Force® CORE (TFC, CNSystems Medizintechnik GmbH, Graz, Austria) together with the Task Force® CARDIO (TFCARDIO, CNSystems Medizintechnik GmbH, Graz, Austria) medical device software, is a new CE-marked medical device for continuous non-invasive determination of blood pressure (BP), cardiac output (CO) and derived parameters based on the well established CNAP® (continuous non-invasive arterial pressure) technology by CNSystems. The primary aim of this prospective, method comparison, open, multi-center study is data acquisition for the performance evaluation of the TFC in comparison with invasive reference methods (i.e. transpulmonary thermodilution, invasive blood pressure with radial artery catheter). The setting of the study will be the Operating Room (OR). This setting allows the comparison of the investigational device's cardiac output (CO) to invasive CO as well as of BP and derived hemodynamic parameters like Stroke Volume (SV), and Systemic Vascular Resistance (SVR). Measurements will be performed during the perioperative period, starting 15 minutes after the first skin incision.

Study Design

Study Type
Observational
Observational Model
Other
Time Perspective
Prospective

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Adult patients (patients aged at least 18 years)
  • Patients undergoing major abdominal surgery who require invasive extended hemodynamic monitoring (trans pulmonary thermodilution via PiCCO and invasive blood pressure monitoring with radial artery catheter) according to clinical standard of care
  • Patients with intact perfusion of both hands evidenced by a positive Allen's test
  • Patients given written informed consent to participate in the study

Exclusion Criteria

  • Patients with vascular impairments at the sites of non-invasive blood pressure measurement (fingers or upper arms)
  • Patients with significant edema in the fingers
  • Patients with ventricular assist devices or extracorporeal life-supporting devices
  • Subjects not passing the Allen's test for both hands
  • Patients who obtain vasoactive medications on the same arm as used for upper-arm Task Force blood pressure measurements
  • Patients with a large lateral difference in blood pressure (> 15mmHg for systolic blood pressure and/or >10 mmHg for diastolic blood pressure) or with same arm measurement differences > 10 mmHg in systolic or diastolic blood pressure during assessment of lateral differences
  • Patients who, in addition to invasive blood pressure monitoring, require non-invasive blood pressure measurements unrelated to the investigational device

Outcomes

Primary Outcomes

Difference in intraoperative cardiac output measurements between Task Force CORE compared with thermodilution during surgery

Time Frame: For the duration of surgery

Intraoperative performance of cardiac output values derived by the Task Force CORE system compared with cardiac output measurements derived by thermodilution measurements.

Secondary Outcomes

  • Differences in intraoperative hemodynamic measurements (stroke volume in ml) between Task Force CORE compared with thermodilution during surgery(For the duration of surgery)
  • Intraoperative continuous Cardioc Output measurements(For the duration of surgery)
  • Differences in intraoperative hemodynamic measurements (stroke volume variation in %) between Task Force CORE compared with thermodilution during surgery(For the duration of surgery)
  • Differences in intraoperative hemodynamic measurements (blood pressure in mmHg) between Task Force CORE compared with thermodilution during surgery(For the duration of surgery)

Investigators

Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Christian Reiterer

Principal Investigator

Medical University of Vienna

Study Sites (1)

Loading locations...

Similar Trials