The Impact of Regional Anaesthesia on Hormone Levels in Thoracic Surgery.

Medical University of Silesia1 个研究点 分布在 1 个国家目标入组 119 人开始时间: 2018年5月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
119
试验地点
1
主要终点
Testosterone concentration. [pg/ml]

研究概览

简要总结

Basic aspects of thoracic anaesthesia are general anesthesia often combined with regional anesthesia, intubation with double lumen tube and separation of lung ventilation. Proper assessment of pain and adequate analgesia in intraoperative and postoperative period is a challenging issue for medical practitioners. Intraoperative trauma may lead to many metabolic implications and disturbance of haemostasis, what can be reflected in change of blood and saliva hormone and other substance levels. The aim of this study is to assess the impact of regional anesthesia on hormone levels in patients requiring videothoracoscopic procedures.

详细描述

Basic aspects of thoracic anaesthesia are general anesthesia often combined with regional anesthesia, intubation with double lumen tube and separation of lung ventilation. Proper assessment of pain and adequate analgesia in intraoperative and postoperative period is a challenging issue for medical practitioners. Intraoperative trauma may lead to many metabolic implications and disturbance of haemostasis, what can be reflected in change of blood and saliva hormone and other substance levels, such as alpha-amylase, cortisol, testosterone, secretory IgA, β-endorphin, nerve growth factor, calcitonin gene-related protein and P substance. The aim of this study is to assess the impact of regional anesthesia on hormone levels in postoperative period. Saliva was collected from participants in order to perform laboratory tests, using a special disposable Salivette tube (Sarstedt AG & Co, Germany). Saliva was collected by placing a sterile tampon under the tongue or chewing for 30-45 seconds. The soaked saliva pad was then placed in a suspended insert with a perforated bottom. The insert with a tampon was placed in a centrifuge tube and closed with a stopper. Next the tube was centrifuged (1000 x g for 10 min.) to obtain a ready to test saliva supernatant. Approximately 0,7 ml of the supernatant from every sample collected was used for further testing. Samples were frozen after centrifugation at - 85°C until performing laboratory tests. Blood was collected for laboratory tests from the ulnar vein. Blood for testing was collected using disposable equipment in a volume of 5ml into a tube containing ethylenediaminetetraacetic acid (EDTA) and aprotinin. Next the tube was centrifuged (1000 x g for 5 min.). After centrifugation and separation of morphotic elements, the obtained plasma was divided into two tubes and frozen at - 85°C until performing laboratory tests.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • qualification to elective videothoracoscopic procedures and general anaesthesia

排除标准

  • lack of consent to participation in the study,
  • significant coagulopathy,
  • contraindication to the thoracic paravertebral block or drugs used in protocol,
  • history of chronic pain,
  • chest wall neoplastic invasion,
  • previous thoracic spine surgery,
  • mental state preventing from effective use of PCA device,
  • renal failure (GFR <60 ml/min/1,73 m2).

结局指标

主要结局

Testosterone concentration. [pg/ml]

时间窗: 24 hours

The commercial ELISA (Diapra, Italy) was used to determine the concentration of testosterone. The analytical procedure was in accordance with the manufacturer's instructions in the technical manuals supplied with the kits. Absorbance readings were taken using a µQuant reader (Biotek, USA), while results were processed using KCJunior (Biotek, USA). The sensitivity of the method was 3,28 pg/ml for testosterone. The method's imprecision was 7.9%. Material was collected after enrollment to the study (T0), six hours after the surgery (T1) and 24 hours after the surgery (T2).

Alpha-amylase activity. [U/ml]

时间窗: 24 hours

α-amylase activity assay was performed by a static method with AMYLAZA kit (Aqua-Med Łodz, Poland). The samples were diluted 100 times using 0,9% chloride solution. 2-chloro-4-nitrofenylo-maltotrioside is a substrate in this method. The reaction was performed in pH 6,0 MES buffer at 37 ° C rendering a colored reaction product. The product was then analyzed via spectrophotometry at 405 nm. Results are presented in salivary α-amylase activity units (U/ml). Measurement imprecision of the method was 4.1%. Material was collected after enrollment to the study (T0), six hours after the surgery (T1) and 24 hours after the surgery (T2).

Cortisol concentration. [ng/ml]

时间窗: 24 hours

The commercial ELISA (Diapra, Italy) was used to determine the concentration of cortisol. The analytical procedure was in accordance with the manufacturer's instructions in the technical manuals supplied with the kits. Absorbance readings were taken using a µQuant reader (Biotek, USA), while results were processed using KCJunior (Biotek, USA). The sensitivity of the method was 0,12 ng/ml for cortisol. The method's imprecision was 6.2%. Material was collected after enrollment to the study (T0), six hours after the surgery (T1) and 24 hours after the surgery (T2).

Secretory Immunoglobulin A concentration. (sIgA)

时间窗: 24 hours

The commercial ELISA (Immunodiagnostic AG, Niemcy.) were used to determine the concentration of sIgA. The analytical procedure was in accordance with the manufacturer's instructions in the technical manuals supplied with the kits. Absorbance readings were taken using a µQuant reader (Biotek, USA), while results were processed using KCJunior (Biotek, USA). Material was collected after enrollment to the study (T0), six hours after the surgery (T1) and 24 hours after the surgery (T2).

β-endorphin concentration.

时间窗: 24 hours

Determination of β-endorphin concentration was preceded by extraction on C18 Sep-Pak columns containing 50mg C18, using trifluoroacetic acid (TFA) and elution buffer (i.e. 60% acetonitrile, 1% TFA and 39% distilled water). The extracts obtained were lyophilized. To determine the concentration of β-endorphins in the tested samples, lyophilisates were dissolved in an appropriate amount of buffer, and then commercial ELISA tests from Elabscience, USA were used. The analytical procedure was in accordance with the manufacturer's instructions in the technical manuals supplied with the kits. Absorbance readings were taken using a µQuant reader (Biotek, USA), while results were processed using KCJunior (Biotek, USA). Material was collected after enrollment to the study (T0), six hours after the surgery (T1) and 24 hours after the surgery (T2).

P substance concentration. [pg/ml]

时间窗: 24 hours

The commercial ELISA test was used to determine the concentration of P substance. The analytical procedure was in accordance with the manufacturer's instructions in the technical manuals supplied with the kits. Material was collected after enrollment to the study (T0), six hours after the surgery (T1) and 24 hours after the surgery (T2).

Nerve Growth Factor concentration. [ng/ml]

时间窗: 24 hours

The commercial ELISA test was used to determine the concentration of the Nerve Growth Factor. The analytical procedure was in accordance with the manufacturer's instructions in the technical manuals supplied with the kits. Material was collected after enrollment to the study (T0), six hours after the surgery (T1) and 24 hours after the surgery (T2).

Calcitonin Gene-related Peptide concentration. [pg/ml]

时间窗: 24 hours

The commercial ELISA test was used to determine the concentration of the Calcitonin Gene-related Peptide. The analytical procedure was in accordance with the manufacturer's instructions in the technical manuals supplied with the kits. Material was collected after enrollment to the study (T0), six hours after the surgery (T1) and 24 hours after the surgery (T2).

次要结局

  • Heart rate [bmp](24 hours)
  • Arterial blood saturation measured by pulse oximetry [%](24 hours)
  • Pain intensity (NRS)(24 hours)
  • Arterial blood pressure [mmHg](24 hours)