Skip to main content
Clinical Trials/NCT03496428
NCT03496428
Completed
Not Applicable

Customized Impressions in Dental Implants - Soft Tissues Changes

Implantology Institute1 site in 1 country6 target enrollmentJune 2, 2017
ConditionsSoft Tissue

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Soft Tissue
Sponsor
Implantology Institute
Enrollment
6
Locations
1
Primary Endpoint
Changes in Soft Tissues Around Implant
Status
Completed
Last Updated
6 years ago

Overview

Brief Summary

Six patients with a single unit implant in the anterior maxilla (from premolar to premolar), after at least 3 months with provisional implant supported restoration will be submitted to definitive implant impressions.

Informed consents and local ethical committee clearance will be obtained. Patients will be submitted to a silicon impression with a customized impression coping from which a conventional cast will be obtained and scanned with D2000 (3Shape) and to an intraoral scan with Trios (3Shape). Standard Tessellation Language (STL) files will be obtained from both procedures and imported to reverse engineering software Geomagic Control X (3D Systems) and the distance between both scans will be calculated in a colored 3D map. From this map, two outcomes will be analyzed: the changes in soft tissues around implants with the two techniques (primary outcome) and the discrepancy between both scans in the teeth adjacent to the implants (secondary outcome).

Detailed Description

"Custom-guided" tissue healing with o provisional restoration is the most predictable way to achieve natural anatomically shaped tissue and optimal esthetics. Several authors describe the use of an anatomically contoured provisional restoration to start to guide the soft tissue healing in an ideal, natural morphology that replicates the tooth form. Being that, after shaping the tissue to ideal anatomic form and health the exact duplication of the soft tissue contour should be obtained so that laboratory can duplicate it in the final restoration. Nowadays gold-standard, describes the use of a customized impression coping that replicates the provisional soft tissue contour by the use of and analog-silicone index upon which a gypsum cast is created. The use of computer-aided design/computer-assisted manufacture (CAD/CAM) technologies to manufacture prosthetic frameworks on dental implants is noticeably increasing. This method requires the use of an STL file which can be acquired intra-orally or extraorally using a stone cast poured from a conventional implant impression using a customized implant impression coping. Several studies have already described the accuracy of STL data and that evaluating STL models can be done by best fit algorithms in appropriate softwares. In this pilot study, the investigators aim to evaluate soft tissue profile changes in single unit implants in the aesthetic area using a customized impression coping with conventional methods and the intraoral impression with an intraoral scanner (Trios, 3Shape). Additionally position discrepancies of adjacent teeth between the two techniques will be assessed. This pilot study will include 6 patients with single unit implant which will be recruited according inclusion criteria and submitted to the two different impression techniques. Conventional stone cast will be scanned with a laboratory scanner D2000 (3Shape) with a described deviation of 5μm. Two STL files will be obtained per patient and by established methods with a reverse engineering software (Geomagic Control X, 3D Systems) discrepancies between them assessed. Differences in axis (x, y, z) and overall distances will be assessed in the soft tissues (18 points) and in adjacent teeth (26 points) according established methods, per patient. Additionally, 3D colored maps will be produced to ascertain volumetric changes between techniques. T-test and Wilcoxon signed-rank test will be used and the level of statistical significance set at P\<0.05. Sample size determination will be performed based on obtained results.

Registry
clinicaltrials.gov
Start Date
June 2, 2017
End Date
September 1, 2018
Last Updated
6 years ago
Study Type
Interventional
Study Design
Single Group
Sex
All

Investigators

Sponsor
Implantology Institute
Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • Patients with single implant with adjacent teeth in the anterior esthetic area (Pre-Molar to Pre-Molar) of the upper arch with provisional implant crown use and indication for rehabilitation for definitive implant supported crown.

Exclusion Criteria

  • Patients without soft tissue contouring or without provisional implant supported use

Outcomes

Primary Outcomes

Changes in Soft Tissues Around Implant

Time Frame: Both techniques will be used in the same appointment upon 3 months use of provisional crown

Discrepancies in soft tissues around implants between different techniques, conventional and digital, in a single unit implant impression, measured as root mean square in µm.

Secondary Outcomes

  • Discrepancy (Trueness) Between STL Files in Teeth Adjacent to Implant(Both techniques will be used in the same appointment upon 3 months use of provisional crown)

Study Sites (1)

Loading locations...

Similar Trials