Efficacy of the echOpen Device to Identify Effusion and to Detect Basilic Vein
- Conditions
- Abdominal EffusionPleural EffusionProcedural Guidance
- Interventions
- Device: EchOpen ultra-portable ultrasound deviceDevice: Ultrasound device routinely used in the department.Procedure: Standard ultrasound examination by an independent referent radiologist
- Registration Number
- NCT05280119
- Lead Sponsor
- Assistance Publique - Hôpitaux de Paris
- Brief Summary
In recent years, portable and ultra-portable ultrasound devices are increasingly used by the non radiologists, notably cardiologists or obstetrician gynecologist, at the patient's bedside to visualize and measure anatomical structures and fluid and provide the clinical examination with additional signs allowing quicker and more confident clinical decisions.
This innovative approach is slowed down by the accessibility of these miniaturized devices, the price of which remains high.
The echOpen device includes an ultra-portable ultrasound probe and a mobile application that allows the image to be displayed on a smartphone via a WIFI protocol.
The objective of the clinical investigation is to show that the echOpen device, using three frequencies 3.5 Mhz, 5.0 Mhz and 7.5 Mhz, allows identifying the semiological signs or anatomical structures of interest located at several depths of the body, with a performance similar to other devices routinely used in clinical departments.
- Detailed Description
The echOpen device includes an ultrasound probe and a mobile application. The mechanical probe emits at three ultrasound frequencies, 3.5 Mhz, 5.0 Mhz and 7.5 Mhz, which allows the exploration of the interior of the body at different depths in a non-invasive and non-irradiating manner.
Thus, the purpose of the echOpen device is, on one hand, to guide the diagnosis during the clinical examination and, on the other hand, to identify anatomical structures in order to assist in management.
The objective of the clinical investigation is to demonstrate that the echOpen device is able to identify semiological signs and localize anatomical structures at different depths of the body, with a performance not inferior to that of other ultrasound devices, routinely employed in hospital clinical departments.
The signs of interest (i.e. search for an intra-abdominal (3.5 Mhz) and pleural (5.0 Mhz) effusion) were chosen for their clinical usefulness (their presence during the clinical examination constitutes an argument for orientation and/or severity) and for their prevalence in the study population.
The identification of anatomical structure of interest (i.e. detection of basilic vein (7.5Mhz)) was chosen because it is a gesture frequently used when taking in charge of a patient hospitalized in the selected departments.
An ultrasound probe in use in the hospital clinical departments where the investigation takes place will be employed as a comparator to judge the performance of the echOpen device.
This clinical investigation is part of a CE marking procedure.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 201
- Adult patient (age ≥ 18 years old)
- Patient having signed the informed consent to participate in this clinical investigation
- Patient affiliated to the social security scheme
- Patient arriving in the hospital clinical ward (own initiative or by emergency services) whose clinical symptomatology (e.g. dyspnea, thoracic pain, etc.) suggests the presence of pathological elements (effusion) which would be visible using an ultrasound probe
- Patient consulting in the hospital clinical ward who could potentially benefit from a basilic vein line placement using an ultrasound device
- Minor patient (age < 18 years)
- Patients under the "State medical assistance"
- Obese patient (body mass index > 29.9)
- Patient in too serious condition for the clinical examination to be done fully and/or with additional exploratory time
- Unstable patient: need for immediate care, impossibility to carry out a thorough clinical examination including interview, palpation, auscultation, percussion
- Known allergy to ultrasound gel
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Patients benefitting ultrasound examination EchOpen ultra-portable ultrasound device This is the only arm of the study. Patients with an indicative clinical picture that leads the clinician to resort to the use of an ultrasound to potentially support the diagnosis will be examined to verify the presence of pleural effusion or intra-abdominal effusion, or to identify basilic vein. The patients will be assessed first with the echOpen device and second witn an ultrasound routinely used in the department. In a case of discordance between the assessments made with echOpen and the usual ultrasound device, an independent referent radiologist will use a standard ultrasound machine to constitute the gold standard (GS) rating Patients benefitting ultrasound examination Ultrasound device routinely used in the department. This is the only arm of the study. Patients with an indicative clinical picture that leads the clinician to resort to the use of an ultrasound to potentially support the diagnosis will be examined to verify the presence of pleural effusion or intra-abdominal effusion, or to identify basilic vein. The patients will be assessed first with the echOpen device and second witn an ultrasound routinely used in the department. In a case of discordance between the assessments made with echOpen and the usual ultrasound device, an independent referent radiologist will use a standard ultrasound machine to constitute the gold standard (GS) rating Patients benefitting ultrasound examination Standard ultrasound examination by an independent referent radiologist This is the only arm of the study. Patients with an indicative clinical picture that leads the clinician to resort to the use of an ultrasound to potentially support the diagnosis will be examined to verify the presence of pleural effusion or intra-abdominal effusion, or to identify basilic vein. The patients will be assessed first with the echOpen device and second witn an ultrasound routinely used in the department. In a case of discordance between the assessments made with echOpen and the usual ultrasound device, an independent referent radiologist will use a standard ultrasound machine to constitute the gold standard (GS) rating
- Primary Outcome Measures
Name Time Method Presence of Pleural effusion Day 0 Presence or absence of pleural effusion as assessed by the echOpen device or by a portable ultrasound routinely used in the department
Presence of Intra-abdominal effusion Day 0 Presence or absence of intra-abdominal effusion as assessed by the echOpen device or by a portable ultrasound routinely used in the department
Basilic vein identification Day 0 Successful identification of the basilic vein using the echOpen device or a portable ultrasound routinely used in the department
- Secondary Outcome Measures
Name Time Method Plural effusion detected using a gold standard procedure Day 0 Presence of pleural effusion determined by an independent referent radiologist using a standard ultrasound machine
Basilic vein identification using a gold standard procedure Day 0 Identification of the basilic vein by an independent referent radiologist using a standard ultrasound machine
Intra-abdominal effusion detected using a gold standard procedure Day 0 Presence or absence of intra-abdominal effusion determined by an independent referent radiologist using a standard ultrasound machine