A Comparison of Unidirectional Valve Apparatus With Occluding the Non-ventilated Endobronchial Lumen for Lung Collapse During Video-associated Thoracoscopy: a Prospective Randomized Controlled Trial.
概览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- Sichuan University
- 入组人数
- 192
- 试验地点
- 1
- 主要终点
- The time needed for satisfactory lung collapse
概览
简要总结
With the rapid advancement of thoracoscopic surgery in recent years, surgeons have set higher standards for the quality of non-ventilated lung collapse. In a prior investigation, we examined a unidirectional valve device that let air exit the non-ventilated side of the lung but not enter during ventilation and showed the use of this device during one-lung ventilation (OLV) for patients undergoing thoracoscopic surgery could speed up lung collapse, lower endogenous positive end-expiratory pressure, and have no discernible effects on oxygenation. In light of this, we conducted this study to further demonstrate, by comparison with the commonly used clinical technique of occluding the non-ventilated endobronchial lumen during one-lung ventilation, that this unidirectional valve device can quicken and enhance the quality of lung collapse without raising the risk of adverse events when used in thoracoscopic surgery.
详细描述
In this study, patients who meet the enrollment criteria will be randomized 1:1 to the unidirectional valve group or the closed lumen group.
After patients entered the operating room, their heart rate, mean arterial pressure, electrocardiogram, and pulse oxygen saturation were monitored. The electrodes of a bispectral index (BIS) Vista monitor were placed on the patient's forehead. The mask for oxygen inhalation at 6 L/min was then applied. Anesthesia was induced with 2mg midazolam, 0.3ug/kg sufentanil, 2-3mg/kg propofol and 0.3mg/kg cisatracurium using ideal body weight. Patients were intubated using a video double-lumen endotracheal tube [Disposable sterile double-lumen tracheal intubation, Nortier] by a senior anesthesiologist. Following confirmation of the double-lumen tube (DLT) placement position, two-lung ventilation was started at a respiratory rate of 15 breaths per minute, with an inspiratory to expiratory (I: E) ratio of 1:2, tidal volume of 8 ml/kg, and an inspired oxygen fraction (FiO2) of 0.8. Remifentanil (0.05-0.3 ug/kg/min) and propofol (4-12 mg/kg/h) were continuously infused to maintain anesthesia while the levels of BIS fluctuated between 40 and 60. The DLT placement location was verified again as soon as the disinfection and draping process started, and one-lung ventilation was initiated. In this study, we used a disposable plastic membrane glove and chopped off the fingers to create a unidirectional valve device. Our prior clinical experiment showed that this device permits gas in the non-ventilated lung to exit during exhalation, while ambient air could not enter via the collapsed cut hole during inhalation. In the unidirectional valve group, as soon as disinfection and draping began, the lumen of the Y-connector to the non-ventilated lung was clamped and the unidirectional valve device was fastened to the bronchoscope port of the tracheal lumen to initial the one-lung ventilation. In the closed lumen group, as soon as disinfection and draping began, the lumen of the Y-connector to the non-ventilated lung was clamped, and the bronchoscope port of the tracheal lumen was sealed off from the atmosphere until pleural opening. When the pleura opened, the bronchoscope port opened to the air for 30 seconds before closing once more until the one-lung ventilation was completed. The tidal volume was adjusted to 6 ml/kg during OLV, and the respiratory rate was set to 15 breaths per minute with a I:E ratio of 1:2 and FiO2 of 0.8. Positive expiratory pressure was not applied in this trial. After pleural opening, the thoracoscopic surgery procedure was captured on video using an electronic equipment. The anesthesiologist, who was blind to the specific lung collapse technique, watched the recordings after surgery and used a visual analogue scale to assess the quality of lung collapse at various time points. Bronchial suction was employed to foster lung collapse of the non-ventilated lung if there was no collapse or partial collapse of the lung during the surgical procedure. The number and timing of bronchial suction should be documented in detail. After surgery, patients were transferred to the post-anesthesia care unit (PACU) for continued monitoring. Throughout their hospital stay, the patients were visited daily, and any postoperative pulmonary issues were recorded in time until the patients were released from the hospital.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Other
- 盲法
- Quadruple (Participant, Care Provider, Investigator, Outcomes Assessor)
盲法说明
To guarantee the blinding of the surgeons and data recorders, a cover was placed over the patient's head and the DLT connector during the surgical operation. An independent investigator, who blinded to treatment assignment, carried out the postoperative assessment of lung collapse quality and subsequent follow-up visits. The anesthesiologist, who performed the DLT intubation, was the only study personnel unblinded to the randomization scheme and was not involved in data collection and analysis.
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age: 18-75 years old
- •American Society of Anesthesiologists (ASA) physical status I to III
- •Patients scheduled to undergo video-associated thoracoscopic surgery requiring one-lung ventilation
排除标准
- •A - pre-operative
- •anticipated difficult intubation
- •New York Heart Association (NYHA) heart failure class III/IV
- •body mass index≥35kg/m2
- •patients with abnormal expiratory recoil \[forced expiratory volume in 1s (FEV1) less than 70% of predicted values
- •chronic obstructive pulmonary disease (COPD) or severe asthma
- •prior thoracic surgery or radiotherapy
- •a history of pleural or interstitial disease
- •B - post-randomization
- •the discovery of pleural adhesions following pleural opening
结局指标
主要结局
The time needed for satisfactory lung collapse
时间窗: The first 24 hours after surgery
The outcome was measured from the initial of one-lung ventilation after clamping the non-ventilated lumen of DLT to the time of satisfactory lung collapse, graded via video view, by an independent investigator who was blinded to the lung collapse technique using a verbal analogue scale (0 = no lung collapse; 10 = total lung collapse). A score of eight for satisfactory lung collapse meant that the lung tissue had essentially collapsed, the surgical field was clearly visible, and the surgeons could carry out routine procedures.
次要结局
- The incidence of postoperative pulmonary complications(During hospital stay, an expected average of one week)
- The quality of lung collapse(The first 24 hours after surgery)
- The development of intraoperative hypoxemia(Up to the end of the thoracoscopic surgery)
- The need for bronchial suction(Up to the end of the thoracoscopic surgery)
研究者
Peng Liang,MD
Professor
West China Hospital