The Effect of Mulligan Mobilization Technique on Balance, Pain and Functionality in Patients With Chronic Low Back Pain
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 37
- 试验地点
- 2
- 主要终点
- Electrogoniometer
研究概览
简要总结
This study was aimed to investigate the effectiveness of mulligan mobilization technique on balance, pain and functionality in patients with chronic low back pain and to compare it with exercise.37 patients aged between 18-65 who applied to Fındıkzade Medipol Hospital were included in the study. The individuals participating in the study were divided into two groups, 18 control and 19 mulligan groups, according to the randomization table. The intervention was performed 3 times a week for 4 weeks. Conventional physiotherapy and exercise program accompanied by a physiotherapist were applied to the control group, and conventional physiotherapy and mulligan mobilization technique were applied to the mulligan group. Conventional physiotherapy methods included ultrasound (US), Transcutaneous Electrical Nerve Stimulation (TENS), and hotpack. The patients were evaluated with TecnoBody Static Balance Device, algometer, electrogoniometer, visual analog scale, Oswestry Low Back Pain Disability Questionnaire before and after the treatment.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Experiencing non-specific chronic low back pain for more than 3 months
- •The diagnosis has been confirmed by the Health Board Report
- •Be over 18 years old
- •Be younger than 65 years old
- •Pain of at least 2 severity according to VAS
- •Voluntarily agree to participate in the study
排除标准
- •Previous lumbar trauma or operation
- •Long-term use of corticosteroids
- •Pregnancy
- •Osteoporosis
- •Systemic Diseases
- •Spinal Deformities
- •Lumbal Stenosis
- •Ankylozone Spondylitis
- •Spondylolisthesis
- •Spinal Deformities
- •Lumbal Stenosis
结局指标
主要结局
Electrogoniometer
时间窗: 5 Minutes
It is an evaluation tool used to record the objective measurement of joint range of motion.
TecnoBody Static Balance Device Measurements
时间窗: 5 Minutes
TecnoBody Stability Easy is a stabilometric system consisting of three highly sensitive sensors. The system is based on continuous observation of the foot pressure center (COP). By recording the postural oscillations of the body as a function of time, detailed information about the postural system is obtained
Pressure Pain-Threshold Measurements with Algometer
时间窗: 5 Minutes
It is a device used to evaluate the sensitivity to pain and to determine the perception of pressure. The pressure algometer has proven useful in evaluating fibrositis and hypersensitive spots, trigger points, arthritis activation, and visceral pain-pressure sensitivity.
次要结局
- Visual Analog Scale(1 Minutes)
- Oswestry Disability Index(10 Minutes)
研究者
Kubra Bali
Principal Investigator
Medipol University
