跳至主要内容
临床试验/NCT03579849
NCT03579849已完成不适用

Pulmonary Perfusion by Iodine Subtraction Mapping CT Angiography in Acute Pulmonary Embolism: a Diagnostic Accuracy Study Versus Pulmonary Perfusion SPECT.

University Hospital, Brest2 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2018年6月25日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
30
试验地点
2
主要终点
The sensitivity of iodine mapping by subtraction technique.

研究概览

简要总结

  • Pulmonary embolism (PE) is a diagnostic and therapeutic challenge. The risk of death of untreated PE is approximately 25%. On the other hand, anticoagulant treatment is associated with a haemorrhagic risk (2% of major haemorrhagic accidents per year, of which 10% are fatal). A diagnostic accuracy is therefore necessary.
  • Two approaches are available to diagnose PE:
  1. A functional approach, represented by pulmonary ventilation / perfusion scintigraphy (V / P), which looks for the functional consequences of PE. The main disadvantage of this approach is that there is a high rate of non-diagnostic examinations. On the other hand, it allows a mapping of pulmonary perfusion at the microcapillary scale, and thus allows the quantification of the vascular obstruction index, which would be an independent risk factor of PE recurrence.
  2. A morphological approach, represented by CT pulmonary angiography (CTPA), which allows the visualisation of the clot itself. This approach is currently the most used but has some limitations, including a risk of over-diagnosis of pulmonary embolism and the inability to reliably quantify the index of vascular obstruction.

Lung subtraction iodine mapping CT is a new technique allowing, during the realization of a CTPA, without additional irradiation, to provide a mapping of the iodine. This mapping of iodine could potentially be used to evaluate pulmonary perfusion.

It would then be possible to obtain, during a single examination, in addition to the anatomical information of the thoracic angioscan, information on the pulmonary perfusion and thus to assess the functional consequences of PE.

No study to date has evaluated the performance of the pulmonary subtraction CT for the evaluation of pulmonary perfusion in the context of acute pulmonary embolism suspicion.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • All patients who have been diagnosed with acute pulmonary embolism on the Aquilion One Genesis scan (Toshiba, Medical System, Tokyo, Japan) at the Brest University Hospital, and who have had a mapping of the iodine derived from the subtraction images.

排除标准

  • Tomoscintigraphy not feasible within 24 hours.
  • Massive pulmonary embolism or with signs of gravity
  • Pregnant or lactating women
  • Minor patient
  • Protected adults
  • Incapacity / refusal to give consent
  • Hypersensitivity to pertechnetate (99m Tc)
  • Hypersensitivity to human albumin

研究组 & 干预措施

Perfusion SPECT

Experimental

Included patients with a diagnosis of acute PE on CTPA and who had a subtraction iodine mapping CT will undergo a SPECT/CT within 24 hours.

Each lung subtraction iodine mapping CT will be interpreted blindly by 3 radiologists. Each of the 20 lung segments will be interpreted as normoperfused or hypoperfused.

Each perfusion SPECT will be interpreted blindly by 3 nuclear medicine physicians. Each of the 20 lung segments will be interpreted as normoperfused or hypoperfused.

干预措施: Pulmonary tomoscintigraphy (Diagnostic Test)

结局指标

主要结局

The sensitivity of iodine mapping by subtraction technique.

时间窗: 24 hours

The sensitivity of iodine mapping by subtraction technique for the detection of perfusion defects in pulmonary embolism is evaluated with using pulmonary perfusion tomoscintigraphy as a reference standard .

次要结局

  • The specificity of iodine mapping by subtraction technique(24 hours)
  • Pulmonary vascular obstruction index(24 hours)
  • Concordance CTPA - iodine substraction(24 hours)
  • Concordance CTPA - SPECT(24 hours)
  • Interobserver reproductibility(24 hours)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验